Siemens F31801 fault code meaning

Siemens / F31801

Series: DCM-6RA80

Encoder 1 DRIVE-CLiQ: Sign of life missing

DC drive

Meaning: %2 Message class: Internal communication (DRIVE-CLiQ) fault (12) Drive object: DC_CTRL, DC_CTRL_R, DC_CTRL_R_S, DC_CTRL_S Component: Control unit (CU) Propagation: LOCAL Reaction: Encoder (IASC/DCBRK, None) Acknowledgment: Immediately Cause: A fault has occurred in DRIVE-CLiQ communication between the control unit and the associated encoder. Fault cause: 10 (= 0A hexadecimal): The sign-of-life bit is not set in the received telegram. Note on the message value: Detailed information is encoded in the message value (r0949/r2124) as follows: 0000yyxx hexadecimal: yy = Component number, xx = Fault cause

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1091

Series: G120-CU250S-2

Encoder 1 DRIVE-CLiQ: Sign of life missing

converter

Meaning: %2 Drive object: CU250S_S, CU250S_S_CAN, CU250S_S_DP, CU250S_S_PN. Reaction: Encoder (IASC/DCBRK, none). Acknowledgment: Immediate. Cause: DRIVE-CLiQ communication between the control unit and the associated encoder is faulty. Fault cause: 10 (= 0A hexadecimal): The sign-of-life bit is not set in the received telegram. Note on the message value: Detailed information is encoded in the message value (r0949/r2124) as follows: 0000yyxx hexadecimal: yy = component number, xx = fault cause. See: p0491 (Motor encoder fault reaction "Encoder").

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1520

Series: G130-G150

Encoder 1 DRIVE-CLiQ: Sign-of-life missing

converter

Meaning:

Possible causes

Source: G150 P939

Series: G220

Motor encoder DRIVE-CLiQ: Heartbeat signal missing

converter

Meaning: %2 Component: Control unit (CU) Reaction: Encoder (IASC/DCBRK, None) Acknowledgment: Immediate Faults and alarms 5.2 List of faults and alarms SINAMICS G220 Converter 1508 Parameter Manual, 07/2026, FW V6.7, A5E51781505C AD

Possible causes

Source: SINAMICS G220 Converter P1510

Series: S110

Encoder 1 DRIVE-CLiQ: Sign of life missing

servo drive

Meaning: %2 Drive object: SERVO_S110-CAN, SERVO_S110-DP, SERVO_S110-PN Reaction: Encoder (IASC/ DC brake, none). Acknowledgment: Immediate. Cause: DRIVE-CLiQ communication between the control unit and the associated encoder is faulty.

Possible causes

Source: SINAMICS S110 P1134

Series: S210

Encoder 1 DRIVE-CLiQ: Sign of life missing

servo drive

Meaning:

Possible causes

Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P935