Siemens F31500 fault code meaning

Siemens / F31500

Series: DCM-6RA80

Encoder 1: Position tracking operating range exceeded

DC drive

Meaning: On a linear axis without modulo compensation, the drive/encoder has exceeded the maximum permissible travel range. When p0411.0 = 1, the maximum travel range for the configured linear axis is p0421 multiplied by 64 (+/- 32 times). When p0411.3 = 1, the maximum travel range for the configured linear axis is the maximum permissible value, up to +/-p0412/2 (number of revolutions rounded down). The maximum possible value depends on the line count (p0408) and the fine resolution (p0419).

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1089

Series: G120-CU250S-2

Encoder 1: Position tracking operating range exceeded

converter

Meaning: On a linear axis without modulo compensation, the drive/encoder exceeded the maximum permissible travel range. When p0411.0 = 1, the maximum travel range of the configured linear axis is 64 times p0421 (+/- 32 times). When p0411.3 = 1, the maximum travel range of the configured linear axis is set to the maximum permissible value, reaching +/-p0412/2 (number of revolutions rounded down). The maximum possible value depends on the line count (p0408) and the fine resolution (p0419).

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1519

Series: G130-G150, S120-S150

Encoder 1: Position tracking operating range exceeded

converter

Meaning: On a linear axis without modulo compensation, the drive/encoder has exceeded the maximum permissible operating range. When p0411.0 = 1, the maximum operating range for the configured linear axis is 64 times p0421 (+/- 32 times). When p0411.3 = 1, the maximum operating range for the configured linear axis is the maximum permissible value, reaching +/-p0412/2 (number of revolutions rounded down). The maximum possible value depends on the line count (p0408) and fine resolution (p0419).

Possible causes

Source: SINAMICS G130_G150 P1817;SINAMICS S120_S150 P3000

Series: G210

Motor encoder: Position tracking operating range exceeded

converter

Meaning: On a linear axis without modulo compensation, the drive/encoder exceeded the maximum permissible travel range. When p0411.0 = 1, the maximum travel range of the configured linear axis is 64 times p0421 (+/- 32 times). When p0411.3 = 1, the maximum travel range of the configured linear axis is the maximum permissible value, reaching +/-p0412/2 (number of revolutions rounded down). The maximum possible value depends on the line count (p0408) and the interpolation resolution (p0419).

Possible causes

Source: SINAMICS G210 converter P1257

Series: G220

Motor encoder: Position tracking operating range exceeded

converter

Meaning:

Possible causes

Source: SINAMICS G220 Converter P1508

Series: S110

Encoder 1: Position tracking operating range exceeded

servo drive

Meaning: On a linear axis without modulo compensation, the drive/encoder has exceeded the maximum permissible operating range. When p0411.0 = 1, the maximum operating range for the configured linear axis is 64 times p0421 (+/- 32 times). When p0411.3 = 1, the maximum operating range for the configured linear axis is the maximum permissible value, reaching +/-p0412/2 (number of revolutions rounded down). The maximum possible value depends on the line count (p0408) and fine resolution (p0419).

Possible causes

Source: SINAMICS S110 P1133