Siemens F31130 fault code meaning
Siemens / F31130
Series: G120-CU250S-2
Encoder 1: Zero pulse and position error during coarse synchronization
converter
Meaning: After pole position initialization using signal C/D, Hall signals, or pole position detection is complete, the detected zero pulse is outside the permissible range. For distance-coded encoders, this check is performed after 2 zero pulses have been crossed. Fine synchronization is not performed. When initialization using signal C/D (p0404) is selected, a check determines whether the zero pulse occurs within a mechanical angle range of +/-18 °. When initialization using Hall signals (p0404) or pole position detection (p1982) is selected, a check determines whether the zero pulse occurs within an electrical angle range of +/-60 °.
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1100
Series: V90
Coarse synchronization zero pulse and position error
servo drive
Meaning: After pole position initialization is complete using signal C/D, Hall signals, or pole position detection, the detected zero pulse is outside the permissible range. On distance-coded encoders, this detection is performed after 2 zero pulses have been crossed. Fine synchronization is not performed. Check the plug connection.
Possible causes
Source: SINAMICS V90 PROFINET, SIMOTICS S-1FL6 Operating Instructions P385