Siemens F31100 fault code meaning

Siemens / F31100

Series: DCM-6RA80

Encoder 1: Zero pulse spacing error

DC drive

Meaning:

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1060

Series: G120-CU250S-2

Encoder 1: Zero pulse spacing error

converter

Meaning: The measured zero pulse spacing does not match the set zero pulse spacing. For distance-coded encoders, the zero pulse spacing is calculated from zero pulses detected in pairs. Therefore, a missing zero pulse in a pair does not trigger a fault and has no effect on the system. Set the zero pulse spacing for zero pulse monitoring in p0425 (rotary encoder) or p0424 (linear encoder).

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1496

Series: G120D

Encoder 1: Zero pulse spacing error

converter

Meaning: The measured zero pulse distance does not match the zero pulse distance setting. When a distance-coded encoder is used, the zero pulse distance is calculated from zero pulses detected in pairs. Therefore, a missing zero pulse from a pair does not trigger a fault and has no effect on the system. Set the zero pulse distance for zero pulse monitoring in p0425 (rotary encoder) or p0424 (linear encoder).

Possible causes

Source: SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P941

Series: G130-G150

Encoder 1: Zero mark distance error

converter

Meaning:

Possible causes

Source: G150 P927

Series: G220

Motor encoder: Zero pulse spacing error

converter

Meaning:

Possible causes

Source: SINAMICS G220 Converter P1480

Series: S110

Encoder 1: Zero pulse spacing error

servo drive

Meaning: The measured zero pulse distance does not match the zero pulse distance setting. When a distance-coded encoder is used, the zero pulse distance is calculated from zero pulses detected in pairs. Therefore, a missing zero pulse from a pair does not trigger a fault and has no effect on the system. Set the zero pulse distance for zero pulse monitoring in p0425 (rotary encoder) or p0424 (linear encoder).

Possible causes

Source: SINAMICS S110 P1111

Series: S120-S150

Encoder 1: Zero pulse spacing error

converter

Meaning:

Possible causes

Source: SINAMICS S120_S150 P2967

Series: V90

Zero pulse distance error

servo drive

Meaning: Therefore, a missing paired zero pulse does not trigger a fault and has no effect on the system. Check the plug connection.

Possible causes

Source: SINAMICS V90 PROFINET, SIMOTICS S-1FL6 Operating Instructions P384