Siemens F30887 fault code meaning
Siemens / F30887
Series: DCM-6RA80
Power unit DRIVE-CLiQ(CU): Component fault
DC drive
Meaning: %2 Message class: Internal communication (DRIVE-CLiQ) fault (12) Drive object: DC_CTRL, DC_CTRL_R, DC_CTRL_R_S, DC_CTRL_S Component: Power section Broadcast: LOCAL Response: OFF2 Acknowledgment: Immediate
Possible causes
Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1057
Series: G120-CU250S-2
Power unit DRIVE-CLiQ(CU): Component fault
converter
Meaning: %2 Drive object: CU250S_S, CU250S_S_CAN, CU250S_S_DP, CU250S_S_PN Reaction: OFF2 Acknowledgment: Immediate Cause: A fault was detected in the associated DRIVE-CLiQ component (power unit). This may be a hardware fault. Fault cause: 32 (= 20 hexadecimal): Telegram header error. 35 (= 23 hexadecimal): Receive error: Telegram buffer memory error. 66 (= 42 hexadecimal): Send error: Telegram buffer memory error. 67 (= 43 hexadecimal): Send error: Telegram buffer memory error. 96 (= 60 hexadecimal): The response arrived too late during runtime measurement.
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1493
Series: G130-G150
Power unit DRIVE-CLiQ(CU): Component fault
converter
Meaning: %2 Message class: Internal communication (DRIVE-CLiQ) fault (12) Drive object: B_INF, VECTOR_G Component: Power component Broadcast: LOCAL Response: OFF2 Acknowledgment: Immediate
Possible causes
Source: SINAMICS G130_G150 P1782
Series: S120-S150
Power unit DRIVE-CLiQ(CU): Component fault
converter
Meaning: %2 Message class: Internal communication (DRIVE-CLiQ) Fault (12) Drive object: A_INF, B_INF, CU_LINK, HLA, R_INF, S_INF, SERVO, SERVO_AC, SERVO_I_AC, VECTOR, VECTOR_AC, VECTOR_I_AC Component: Power component Broadcast: LOCAL Response: OFF2 Acknowledgment: Immediate
Possible causes
Source: SINAMICS S120_S150 P2963