Siemens F30885 fault code meaning

Siemens / F30885

Series: DCM-6RA80

Power unit CU DRIVE-CLiQ(CU): Cyclic data transfer fault

DC drive

Meaning: %2 Message class: Internal communication (DRIVE-CLiQ) fault (12) Drive object: DC_CTRL, DC_CTRL_R, DC_CTRL_R_S, DC_CTRL_S Component: Power section Propagation: LOCAL Reaction: OFF2 Acknowledgment: Immediately Cause: A fault has occurred in DRIVE-CLiQ communication between the control unit and the associated power unit. Node transmission and reception are not synchronized. Fault cause: 26 (= 1A hexadecimal): The sign-of-life bit is not set in the received telegram, and the telegram was received too early. 33 (= 21 hexadecimal): The cyclic telegram has not yet arrived. 34 (= 22 hexadecimal): Timing error in the telegram receive list. 64 (= 40 hexadecimal): Timing error in the telegram send list. 98 (= 62 hexadecimal): Error during transition to cyclic operation. Note on the message value: Detailed information is encoded in the message value (r0949/r2124) as follows: 0000yyxx hexadecimal: yy = Component number

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1057

Series: G120-CU250S-2

Power unit CU DRIVE-CLiQ(CU): Cyclic data transfer fault

converter

Meaning:

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1493

Series: G130-G150

Power unit CU DRIVE-CLiQ(CU): Cyclic data transfer fault

converter

Meaning: %2 Message class: Internal communication (DRIVE-CLiQ) fault (12) Drive object: B_INF, VECTOR_G Component: Power section Broadcast: LOCAL Reaction: OFF2 Acknowledgment: Immediately Cause: Fault in DRIVE-CLiQ communication between the control unit and the associated power unit. Node transmission and reception are not synchronized. Fault cause: 26 (= 1A hexadecimal): The sign-of-life bit is not set in the received telegram, and the telegram was received too early. 33 (= 21 hexadecimal): The cyclic telegram has not yet arrived. 34 (= 22 hexadecimal): Timing error in the telegram receive list. 64 (= 40 hexadecimal): Timing error in the telegram send list. 98 (= 62 hexadecimal): Error during transition to cyclic operation. Note on the message value: Detailed information is encoded in the message value (r0949/r2124) as follows: 0000yyxx hexadecimal: yy = Component number, xx = Fault cause

Possible causes

Source: SINAMICS G130_G150 P1782

Series: S120-S150

Power unit CU DRIVE-CLiQ(CU): Cyclic data transfer fault

converter

Meaning: %2 Message class: Internal communication (DRIVE-CLiQ) fault (12) Drive object: A_INF, B_INF, CU_LINK, HLA, R_INF, S_INF, SERVO, SERVO_AC, SERVO_I_AC, VECTOR, VECTOR_AC, VECTOR_I_AC Component: Power section Broadcast: LOCAL Reaction: OFF2 Acknowledgment: Immediate Cause: DRIVE-CLiQ communication between the Control Unit and the associated power unit is faulty. Node transmission and reception are not synchronized. Fault cause: 26 (= 1A hexadecimal): The sign-of-life bit is not set in the received telegram, and the telegram arrived too early. 33 (= 21 hexadecimal): The cyclic telegram has not yet arrived. 34 (= 22 hexadecimal): Timing error in the telegram receive list. 64 (= 40 hexadecimal): Timing error in the telegram send list. 98 (= 62 hexadecimal): Error during transition to cyclic operation. Note on the message value

Possible causes

Source: SINAMICS S120_S150 P2963

Series: S200

Power unit (CU): Cyclic data transmission error

servo drive

Meaning:

Possible causes

Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P577