Siemens F30860 fault code meaning
Siemens / F30860
Series: DCM-6RA80
Power unit DRIVE-CLiQ (CU): Telegram fault
DC drive
Meaning: %2 Message class: Internal communication (DRIVE-CLiQ) fault (12) Drive object: DC_CTRL, DC_CTRL_R, DC_CTRL_R_S, DC_CTRL_S Component: Power section Broadcast: LOCAL Response: OFF2 Acknowledgment: Immediate
Possible causes
Source: SINAMICS DCM, Parameter Manual, Firmware Version 1.5 SP2 (based on 5.1 SP2) P1055
Series: G130-G150
Power unit DRIVE-CLiQ (CU): Telegram fault
converter
Meaning: %2 Message class: Internal communication (DRIVE-CLiQ) fault (12) Drive object: B_INF, VECTOR_G Component: Power component Broadcast: LOCAL Response: OFF2 Acknowledgment: Immediate
Possible causes
Source: SINAMICS G130_G150 P1780
Series: G200
Power unit DRIVE-CLiQ: Telegram error
converter
Meaning: %2 Component: Power unit Reaction: OFF2 Acknowledgment: Immediate System messages 14.3 Faults and alarms SINAMICS G200 Converter Operating Instructions, 06/2026, FW V6.7, A5E54053464B AA 777
Possible causes
Source: SINAMICS G200 Converter P779
Series: G210
Power unit DRIVE-CLiQ: Telegram error
converter
Meaning: %2 Component: Power unit. Broadcast: Local. Response: OFF2. Acknowledgment: Immediate. Faults and alarms 5.2 Fault and alarm list SINAMICS G210 converter 1218 Parameter Manual, 07/2026, FW V6.7, A5E54375461F AA
Possible causes
Source: SINAMICS G210 converter P1220
Series: G210X
Power unit DRIVE-CLiQ: Telegram error
converter
Meaning: %2 Component: Power unit. Broadcast: Local. Response: OFF2. Acknowledgment: Immediate. Faults and alarms 5.2 List of faults and alarms SINAMICS G210X Converter 1044 Parameter Manual, 07/2026, FW V6.7, A5E54375466F AA
Possible causes
Source: SINAMICS G210X Converter P1046
Series: G220
Power unit DRIVE-CLiQ: Telegram error
converter
Meaning: %2 Component: Power unit Reaction: OFF2 Acknowledgment: Immediate Faults and alarms 5.2 List of faults and alarms SINAMICS G220 Converter Parameter Manual, 07/2026, FW V6.7, A5E51781505C AD 1473
Possible causes
Source: SINAMICS G220 Converter P1475
Series: S120-S150
Power unit DRIVE-CLiQ (CU): Telegram fault
converter
Meaning: %2 Message class: Internal communication (DRIVE-CLiQ) Fault (12) Drive object: A_INF, B_INF, CU_LINK, HLA, R_INF, S_INF, SERVO, SERVO_AC, SERVO_I_AC, VECTOR, VECTOR_AC, VECTOR_I_AC Component: Power component Broadcast: LOCAL Response: OFF2 Acknowledgment: Immediate
Possible causes
Source: SINAMICS S120_S150 P2961
Series: S200
Power unit (CU): Telegram failure
servo drive
Meaning: %2 Component: Power unit Response: OFF2 Acknowledgment: Immediate System messages 12.3 Faults and alarms SINAMICS S200 Compact servo drive system with SIMOTICS S-1FL2 or S-1FL1 Operating Instructions, 10/2025, FW V6.5 HF1, A5E54029715B AB 543
Possible causes
Source: SINAMICS S200 Compact_SIMOTICS S-1FL2 and S-1FL1 P545
Series: S210
Power unit DRIVE-CLiQ (CU): Telegram error
servo drive
Meaning: %2 Component: Power unit Propagation: Local Response: OFF2 Acknowledgment: Immediate Faults and alarms 18.2 Fault and alarm list SINAMICS S210 Servo Drive System with SIMOTICS S-1FK2 and S-1FT2 1370 Operating Instructions, 05/2025, FW V6.4, A5E52380168F AF
Possible causes
Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1372
Series: S220
Power unit DRIVE-CLiQ (CU): Telegram error
converter
Meaning: %2 Model: Servo, Vector Component: Power unit Broadcast: Local Response: OFF2 Acknowledgment: Immediate Faults and alarms 5.5 List of faults and alarms SINAMICS S220 Converter 2496 Parameter Manual, 08/2026, FW V6.7, A5E53307549F AB
Possible causes
Source: SINAMICS S220 converter P2498