Siemens F30860 fault code meaning

Siemens / F30860

Series: DCM-6RA80

Power unit DRIVE-CLiQ (CU): Telegram fault

DC drive

Meaning: %2 Message class: Internal communication (DRIVE-CLiQ) fault (12) Drive object: DC_CTRL, DC_CTRL_R, DC_CTRL_R_S, DC_CTRL_S Component: Power section Broadcast: LOCAL Response: OFF2 Acknowledgment: Immediate

Possible causes

Source: SINAMICS DCM, Parameter Manual, Firmware Version 1.5 SP2 (based on 5.1 SP2) P1055

Series: G130-G150

Power unit DRIVE-CLiQ (CU): Telegram fault

converter

Meaning: %2 Message class: Internal communication (DRIVE-CLiQ) fault (12) Drive object: B_INF, VECTOR_G Component: Power component Broadcast: LOCAL Response: OFF2 Acknowledgment: Immediate

Possible causes

Source: SINAMICS G130_G150 P1780

Series: G200

Power unit DRIVE-CLiQ: Telegram error

converter

Meaning: %2 Component: Power unit Reaction: OFF2 Acknowledgment: Immediate System messages 14.3 Faults and alarms SINAMICS G200 Converter Operating Instructions, 06/2026, FW V6.7, A5E54053464B AA 777

Possible causes

Source: SINAMICS G200 Converter P779

Series: G210

Power unit DRIVE-CLiQ: Telegram error

converter

Meaning: %2 Component: Power unit. Broadcast: Local. Response: OFF2. Acknowledgment: Immediate. Faults and alarms 5.2 Fault and alarm list SINAMICS G210 converter 1218 Parameter Manual, 07/2026, FW V6.7, A5E54375461F AA

Possible causes

Source: SINAMICS G210 converter P1220

Series: G210X

Power unit DRIVE-CLiQ: Telegram error

converter

Meaning: %2 Component: Power unit. Broadcast: Local. Response: OFF2. Acknowledgment: Immediate. Faults and alarms 5.2 List of faults and alarms SINAMICS G210X Converter 1044 Parameter Manual, 07/2026, FW V6.7, A5E54375466F AA

Possible causes

Source: SINAMICS G210X Converter P1046

Series: G220

Power unit DRIVE-CLiQ: Telegram error

converter

Meaning: %2 Component: Power unit Reaction: OFF2 Acknowledgment: Immediate Faults and alarms 5.2 List of faults and alarms SINAMICS G220 Converter Parameter Manual, 07/2026, FW V6.7, A5E51781505C AD 1473

Possible causes

Source: SINAMICS G220 Converter P1475

Series: S120-S150

Power unit DRIVE-CLiQ (CU): Telegram fault

converter

Meaning: %2 Message class: Internal communication (DRIVE-CLiQ) Fault (12) Drive object: A_INF, B_INF, CU_LINK, HLA, R_INF, S_INF, SERVO, SERVO_AC, SERVO_I_AC, VECTOR, VECTOR_AC, VECTOR_I_AC Component: Power component Broadcast: LOCAL Response: OFF2 Acknowledgment: Immediate

Possible causes

Source: SINAMICS S120_S150 P2961

Series: S200

Power unit (CU): Telegram failure

servo drive

Meaning: %2 Component: Power unit Response: OFF2 Acknowledgment: Immediate System messages 12.3 Faults and alarms SINAMICS S200 Compact servo drive system with SIMOTICS S-1FL2 or S-1FL1 Operating Instructions, 10/2025, FW V6.5 HF1, A5E54029715B AB 543

Possible causes

Source: SINAMICS S200 Compact_SIMOTICS S-1FL2 and S-1FL1 P545

Series: S210

Power unit DRIVE-CLiQ (CU): Telegram error

servo drive

Meaning: %2 Component: Power unit Propagation: Local Response: OFF2 Acknowledgment: Immediate Faults and alarms 18.2 Fault and alarm list SINAMICS S210 Servo Drive System with SIMOTICS S-1FK2 and S-1FT2 1370 Operating Instructions, 05/2025, FW V6.4, A5E52380168F AF

Possible causes

Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1372

Series: S220

Power unit DRIVE-CLiQ (CU): Telegram error

converter

Meaning: %2 Model: Servo, Vector Component: Power unit Broadcast: Local Response: OFF2 Acknowledgment: Immediate Faults and alarms 5.5 List of faults and alarms SINAMICS S220 Converter 2496 Parameter Manual, 08/2026, FW V6.7, A5E53307549F AB

Possible causes

Source: SINAMICS S220 converter P2498