Siemens F30836 fault code meaning
Siemens / F30836
Series: DCM-6RA80
Power unit DRIVE-CLiQ: DRIVE-CLiQ data transmission error
DC drive
Meaning: %2 Message class: Internal communication (DRIVE-CLiQ) fault (12) Drive object: DC_CTRL, DC_CTRL_R, DC_CTRL_R_S, DC_CTRL_S Component: Power section Propagation: LOCAL Reaction: OFF2 Acknowledgment: Immediately Cause: A fault has occurred in DRIVE-CLiQ communication between the control unit and the associated power unit. Data cannot be sent. Fault cause: 65 (= 41 hexadecimal): Telegram type mismatch with the send list. Note on the message value: Detailed information is encoded in the message value (r0949/r2124) as follows: 0000yyxx hexadecimal: yy = Component number, xx = Fault cause
Possible causes
Source: SINAMICS DCM, Parameter Manual, Firmware Version 1.5 SP2 (based on 5.1 SP2) P1054
Series: G120-CU250S-2
Power unit DRIVE-CLiQ: DRIVE-CLiQ data transmission error
converter
Meaning:
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1489
Series: G130-G150
Power unit DRIVE-CLiQ: DRIVE-CLiQ data transmission error
converter
Meaning: %2 Message class: Internal communication (DRIVE-CLiQ) fault (12) Drive object: B_INF, VECTOR_G Component: Power section Broadcast: LOCAL Reaction: OFF2 Acknowledgment: Immediate Cause: A fault is present in DRIVE-CLiQ communication between the control unit and the associated power unit. Data cannot be sent. Fault cause: 65 (= 41 hexadecimal): The telegram type does not match the send list. Note on the message value: Detailed information is encoded in the message value (r0949/r2124) as follows: 0000yyxx hexadecimal: yy = component number, xx = fault cause.
Possible causes
Source: SINAMICS G130_G150 P1778
Series: G220
Power unit DRIVE-CLiQ: DRIVE-CLiQ data transmission error
converter
Meaning: %2 Component: Power unit Reaction: OFF2 Acknowledgment: Immediate Cause: DRIVE-CLiQ communication error between the converter and the associated power unit. Cannot send data.
Possible causes
Source: SINAMICS G220 converter P1473
Series: S120-S150
Power unit DRIVE-CLiQ: DRIVE-CLiQ data transmission error
converter
Meaning: %2 Message class: Internal communication (DRIVE-CLiQ) fault (12) Drive object: A_INF, B_INF, HLA, R_INF, S_INF, SERVO, SERVO_AC, SERVO_I_AC, VECTOR, VECTOR_AC, VECTOR_I_AC Component: Power section Broadcast: LOCAL Reaction: OFF2 Acknowledgment: Immediate Cause: DRIVE-CLiQ communication between the Control Unit and the associated power unit is faulty. Data cannot be sent. Fault cause: 65 (= 41 hexadecimal): Telegram type mismatch with the send list. Note on the message value: Detailed information is encoded in the message value (r0949/r2124) as follows: 0000yyxx hexadecimal: yy = component number, xx = fault cause
Possible causes
Source: SINAMICS S120_S150 P2959
Series: S200
Power unit: Send error
servo drive
Meaning:
Possible causes
Source: SINAMICS S200 Compact_SIMOTICS S-1FL2 and S-1FL1 P544
Series: S220
Power unit DRIVE-CLiQ: DRIVE-CLiQ data transmission error
converter
Meaning:
Possible causes
Source: SINAMICS S220 converter P2496