Siemens F30820 fault code meaning

Siemens / F30820

Series: DCM-6RA80

Power unit DRIVE-CLiQ: Telegram fault

DC drive

Meaning: %2 Message class: Internal communication (DRIVE-CLiQ) fault (12) Drive object: DC_CTRL, DC_CTRL_R, DC_CTRL_R_S, DC_CTRL_S Component: Power section Broadcast: LOCAL Response: OFF2 Acknowledgment: Immediate

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1052

Series: G120-CU250S-2

Power unit DRIVE-CLiQ: Telegram fault

converter

Meaning: %2 Drive object: CU250S_S, CU250S_S_CAN, CU250S_S_DP, CU250S_S_PN Reaction: OFF2 Acknowledgment: Immediate Cause: Fault in DRIVE-CLiQ communication between the control unit and the associated power unit. Fault cause: 1 (= 01 hexadecimal): Checksum error (CRC error). 2 (= 02 hexadecimal): The telegram is shorter than the specified byte length or the length specified in the receive list. 3 (= 03 hexadecimal): The telegram is longer than the specified byte length or the length specified in the receive list. 4 (= 04 hexadecimal): Received telegram length mismatch with the receive list. 5 (= 05 hexadecimal): Received telegram type mismatch with the receive list. 6 (= 06 hexadecimal): Component address mismatch between the telegram and the receive list. 7 (= 07 hexadecimal): Waiting for a SYNC telegram, but a different telegram was received. 8 (= 08 hexadecimal): A SYNC telegram was received although it was not expected.

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1488

Series: G130-G150

Power unit DRIVE-CLiQ: Telegram error

converter

Meaning:

Possible causes

Source: G150 P923

Series: G200

Power unit DRIVE-CLiQ: Telegram error

converter

Meaning: %2 Component: Power unit Reaction: OFF2 Acknowledgment: Immediate System messages 14.3 Faults and alarms SINAMICS G200 Basic converter 648 Operating Instructions, 12/2025, FW V6.6, A5E54053398B AA

Possible causes

Source: SINAMICS G200 Basic converter P650

Series: G210

Power unit DRIVE-CLiQ: Telegram error

converter

Meaning: %2 Component: Power unit. Broadcast: Local. Response: OFF2. Acknowledgment: Immediate. Faults and alarms 5.2 Fault and alarm list SINAMICS G210 converter 1214 Parameter Manual, 07/2026, FW V6.7, A5E54375461F AA

Possible causes

Source: SINAMICS G210 converter P1216

Series: G210X

Power unit DRIVE-CLiQ: Telegram error

converter

Meaning: %2 Component: Power unit. Broadcast: Local. Response: OFF2. Acknowledgment: Immediate. Faults and alarms 5.2 List of faults and alarms SINAMICS G210X Converter 1040 Parameter Manual, 07/2026, FW V6.7, A5E54375466F AA

Possible causes

Source: SINAMICS G210X Converter P1042

Series: S200

Power unit: Telegram failure

servo drive

Meaning: %2 Component: Power unit Response: OFF2 Acknowledgment: Immediate System messages 12.3 Faults and alarms SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2 570 Operating Instructions, 06/2026, FW V6.7, A5E51646752F AG

Possible causes

Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P572