Siemens F30683 fault code meaning

Siemens / F30683

Series: G120-CU240B-E-2, G120-CU250S-2

SI motion P2: SLS enable missing

converter

Meaning: Safety function "SLS" is not enabled in p9301, although other safety monitoring functions are enabled.

Possible causes

Source: SINAMICS G120, Control Unit CU240B-2_CU240E-2 P779; SINAMICS G120, Control Unit CU250S-2 P1481

Series: S110

SI motion MM: SOS/SLS enable missing

servo drive

Meaning: The basic safety function "SOS/SLS" is not enabled in p9301, although other safety monitoring functions are enabled.

Possible causes

Source: SINAMICS S110 P1099

Series: S210

SI motion P2: SOS/SLS enable missing

servo drive

Meaning: The basic safety function "SOS/SLS" is not enabled, although other safety monitoring functions are enabled.

Possible causes

Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P921