Siemens F30650 fault code meaning

Siemens / F30650

Series: G115D, G120D

SI P2: Acceptance test required

converter

Meaning: The drive-integrated “Safety Integrated” function on processor 2 requires an acceptance test.

Possible causes

Source: SINAMICS G115D P805; SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P927

Series: G120-CU240B-E-2

SI P2: Acceptance test required

converter

Meaning: The drive auto control function "Safety Integrated" on processor 2 requires an acceptance test. Note: This fault results in STOP A, which can be acknowledged.

Possible causes

Source: SINAMICS G120 Control Unit CU240B_E-2 P695

Series: G130-G150

SI MM: Acceptance test required

converter

Meaning:

Possible causes

Source: G150 P919

Series: S110

Fault value: 1000

servo drive

Meaning:

Possible causes

Source: SINAMICS S110 Function Manual P434

Series: S120-S150

SI MM: Acceptance test required), fault value = 130 (Safety of the motor module

converter

Meaning:

Possible causes

Source: SINAMICS S120 Safety Integrated Function Manual P312