Siemens F30604 fault code meaning

Siemens / F30604

Series: G200, G220, S220

SI: Safety EEPROM data error

converter

Meaning: The safety-related EEPROM data is incorrect. This message causes STO (Safe Torque Off). Message value (r60049, decimal): For internal fault diagnostics only.

Possible causes

Source: SINAMICS G200 converter P772; SINAMICS G220 converter P1468; SINAMICS S220 converter P2491

Series: G210, G210X

SI: Safety EEPROM data error

converter

Meaning:

Possible causes

Source: SINAMICS G210 converter P1212; SINAMICS G210X converter P1038

Series: S200

SI: Safety EEPROM data error

servo drive

Meaning: The safety-related EEPROM data is incorrect. This message causes STO (Safe Torque Off). Message value (r60049, decimal): For internal fault diagnostics only.

Possible causes

Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P569

Series: S210

SI: safety EEPROM data error

servo drive

Meaning: Safety-related EEPROM data is incorrect. This message causes STO (Safe Torque Off). Message value (r60049, decimal): For Siemens internal fault diagnostics only.

Possible causes

Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1370