Siemens F30015 fault code meaning
Siemens / F30015
Series: G110M, G115D, G120C, G120D
Power unit: Phase loss in motor supply cable
converter
Meaning: Phase loss has occurred in the motor supply cable. This message is also output under the following conditions: - The motor is correctly connected, but the drive stalls in V/f control. In this case, due to current imbalance, the current measured in one phase is 0 A. - The motor is correctly connected, but the speed loop is unstable, resulting in continuously oscillating torque.
Possible causes
Source: SINAMICS G110M P737; SINAMICS G115D P792; SINAMICS G120C P706; SINAMICS G120D control unit CU240D- 2_CU250D- 2 P915
Series: G120-CU230P-2, G120P-Cabinet
Motor power cable phase loss
converter
Meaning:
Possible causes
Source: Converter SINAMICS G120, equipped with Control Unit CU230P-2 P496; SINAMICS G120P Cabinet P515
Series: G120-CU240B-E-2
Power unit: Phase loss in motor supply cable
converter
Meaning: Phase loss occurred in the motor supply cable. This message is also output under the following conditions: - The motor is correctly connected, but pull-out detection occurs during V/f control. In this case, a current of 0 A is measured in one phase due to current imbalance. - The motor is correctly connected, but the speed loop is unstable, causing continuously oscillating torque. Note: Phase loss monitoring is not performed on chassis and cabinet power units.
Possible causes
Source: SINAMICS G120 Control Unit CU240B_E-2 P686
Series: G120-CU250S-2, G130-G150
Power unit: Phase loss in motor supply cable
converter
Meaning: Phase loss occurred in the motor supply cable. This message is also output in the following cases: - The motor is connected correctly, but the drive loses synchronism in V/f control. Due to current imbalance, the current measured in one phase is 0 A. - The motor is connected correctly, but the speed control loop is unstable, resulting in continuously oscillating torque.
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1455; SINAMICS G130_G150 P1717
Series: G120X, G120XA
Power unit: Phase loss in motor supply cable
converter
Meaning: Phase loss has occurred in the motor supply cable. This message is also issued under the following conditions: - The motor is correctly connected, but pull-out detection occurs in the drive under V/f control. Due to the current imbalance, a current of 0 A is measured in one phase. - The motor is correctly connected, but the speed loop is unstable, producing continuously oscillating torque.
Possible causes
Source: SINAMICS G120X Converter P1405; SINAMICS G120XA PN Converter P1315
Series: G200
Power unit: Phase loss in the motor supply cable
converter
Meaning: Phase loss occurred in the motor cable. This message is also output under the following conditions: - The motor is connected correctly, but pull-out detection occurs in the drive under V/f control. In this case, due to current imbalance, a current of 0 A is measured in one phase. - The motor is connected correctly, but the speed controller is unstable, resulting in continuously oscillating torque. Note: Phase loss monitoring is not performed on chassis and cabinet power units.
Possible causes
Source: SINAMICS G200 converter P749
Series: S110
Power unit: Phase loss in motor supply cable
servo drive
Meaning: Phase loss has occurred in the motor supply cable. This message is also output under the following condition: - The motor is connected correctly, but the speed control loop is unstable, resulting in continuously oscillating torque.
Possible causes
Source: SINAMICS S110 P1074
Series: S200
Power unit: Phase loss in the motor supply cable
servo drive
Meaning: Phase loss has occurred in the motor cable. This message is also output in the following situation: - The motor is connected correctly, but the speed controller is unstable, causing continuously oscillating torque. Note: Phase loss monitoring is not performed on chassis-format power units.
Possible causes
Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P551
Series: S210
Drive: Motor cable phase loss
servo drive
Meaning: Phase loss has occurred in the motor supply cable. This message is also output when the motor is connected correctly but the speed controller is unstable, producing continuously oscillating torque.
Possible causes
Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1351
Series: V90
Power cable phase loss
servo drive
Meaning: A phase fault has been detected in the motor feeder. The signal may also be issued when the motor is correctly connected but the speed loop is unstable, resulting in continuously oscillating torque.
Possible causes
Source: SINAMICS V90 PROFINET, SIMOTICS S-1FL6 Operating Instructions P382