Siemens F30011 fault code meaning
Siemens / F30011
Series: DCM-6RA80
Power unit: Phase loss in the main circuit
DC drive
Meaning:
Possible causes
Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1036
Series: G110M, G115D, G120-CU240B-E-2, G120-CU250S-2, G120C, G120D
Power unit: Phase loss in the main circuit
converter
Meaning: The DC bus voltage ripple at the power unit has exceeded the permissible limit. Possible causes: - Phase loss in one power supply phase. - Impermissible imbalance across the 3 power supply phases. - The DC bus capacitance forms a resonant frequency with the power supply inductance and any reactor integrated into the power unit. - A fuse in one phase of the main circuit has failed. - Phase loss in one motor phase.
Possible causes
Source: SINAMICS G110M P736; SINAMICS G115D P791; SINAMICS G120, control unit CU240B-2_CU240E-2 P761; SINAMICS G120, control unit CU250S-2 P1017; SINAMICS G120C P705; SINAMICS G120D control unit CU240D- 2_CU250D- 2 P915
Series: G120-CU230P-2, G120P-Cabinet
Main power supply phase loss
converter
Meaning:
Possible causes
Source: Converter SINAMICS G120, equipped with Control Unit CU230P-2 P496; SINAMICS G120P Cabinet P515
Series: G120X
Power unit: Phase loss in the main circuit
converter
Meaning: The DC bus voltage ripple at the power unit has exceeded the permissible limit. Possible causes: - Phase loss in one power supply phase. - Impermissible imbalance across all 3 power supply phases. - The DC bus capacitor capacitance, together with the supply inductance and any reactor integrated into the power unit, produces a resonant frequency. - A fuse in one phase of the main circuit has failed. - Phase loss in one motor phase.
Possible causes
Source: SINAMICS G120X converter P1404
Series: G120XA
Power unit: Phase loss in the main circuit
converter
Meaning:
Possible causes
Source: SINAMICS G120XA PN Converter Compact Operating Instructions P8
Series: G130-G150, S120-S150
Power unit: Phase loss in the main circuit
converter
Meaning: The DC bus voltage ripple at the power unit has exceeded the permissible limit. Possible causes: - Phase loss in one phase of the power supply. - Impermissible imbalance across all 3 phases of the power supply. - The DC bus capacitance forms a resonant frequency with the power supply inductance and any reactor integrated into the power unit. - A fuse in one phase of the main circuit has failed. - Phase loss in one motor phase. - The permissible active power of the single-phase power unit has been exceeded.
Possible causes
Source: SINAMICS G130_G150 P1715; SINAMICS S120_S150 P2882
Series: G200
Power unit: Mains imbalance
converter
Meaning: The DC bus voltage ripple at the power unit exceeded the applicable limit for too long. A frequency error was detected, indicating possible mains imbalance or phase loss. Motor phase loss is also possible. Possible causes: - Loss of a mains phase. - Excessive asymmetry across all three phases of the power supply. - The capacitance of the DC bus capacitors, the power supply inductance, and any reactors integrated into the power unit together form a resonant frequency. - Failure of a fuse in one phase of the main circuit. - Loss of a motor phase. - The permissible active power of the single-phase power unit was exceeded.
Possible causes
Source: SINAMICS G200 Basic converter P622
Series: G220
Power unit: Mains imbalance
converter
Meaning: The DC bus voltage ripple in the power unit has exceeded the applicable limit for too long. A frequency error has been detected, indicating possible mains imbalance or phase loss. Motor phase loss is also possible. Possible causes: - Loss of a mains phase. - Excessive imbalance across the three power supply phases. - The capacitance of the DC bus capacitors, the power supply inductance, and any reactor integrated into the power unit together produce a resonant frequency. - A fuse in one phase of the main circuit has failed. - Loss of a motor phase. - The permissible active power of the single-phase power unit has been exceeded.
Possible causes
Source: SINAMICS G220 Converter P1444
Series: S110
Power unit: Phase loss in the main circuit
servo drive
Meaning: The DC bus voltage ripple at the power unit has exceeded the permissible limit. Possible causes: - Phase loss in one power supply phase. - Impermissible imbalance across the 3 power supply phases. - The DC bus capacitance forms a resonant frequency with the power supply inductance and any reactor integrated into the power unit. - A fuse in one phase of the main circuit has failed. - Phase loss in one motor phase.
Possible causes
Source: SINAMICS S110 P1073
Series: S200
Power unit: Mains imbalance
servo drive
Meaning: The DC bus voltage ripple in the power unit has exceeded the applicable limit for too long. A frequency error has been detected, indicating possible mains imbalance or phase loss. Motor phase loss is also possible. Possible causes: - Loss of a mains phase. - Excessive imbalance across the three power supply phases. - The capacitance of the DC bus capacitors, the power supply inductance, and any reactor integrated into the power unit together produce a resonant frequency. - A fuse in one phase of the main circuit has failed. - Loss of a motor phase. - The permissible active power of the single-phase power unit has been exceeded.
Possible causes
Source: SINAMICS S200 Spindle Drive P412
Series: S210
Power unit: Phase loss in the main circuit
servo drive
Meaning: The DC bus voltage ripple in the power unit has exceeded the permissible limit. Possible causes: - Phase loss in one supply phase. - Impermissible imbalance across the 3 supply phases. - The DC bus capacitance, together with the supply inductance and any reactors integrated into the power unit, forms a resonant frequency. - A fuse in one phase of the main circuit has failed. - Phase loss in one motor phase. - The permissible active power of the single-phase power unit has been exceeded.
Possible causes
Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P902
Series: S220
Power unit: Mains imbalance
converter
Meaning:
Possible causes
Source: SINAMICS S220 converter P2451
Series: V90
Main circuit phase loss
servo drive
Meaning: The DC bus voltage ripple at the power unit has exceeded the permissible limit. Possible causes: Phase loss in one power supply phase. Impermissible imbalance across all 3 power supply phases. Fuse failure in one phase of the main circuit. Phase loss in one motor phase.
Possible causes
Source: SINAMICS V90 PROFINET, SIMOTICS S-1FL6 Operating Instructions P382