Siemens F30004 fault code meaning

Siemens / F30004

Series: DCM-6RA80

Power unit: Inverter heatsink overheat

DC drive

Meaning: The power unit heatsink temperature exceeded the permissible limit. - Insufficient ventilation or fan fault. - Overload. - Ambient temperature too high. - Pulse frequency too high.

Possible causes

Source: SINAMICS DCM, Parameter Manual, Firmware Version 1.5 SP2 (based on 5.1 SP2) P1035

Series: G110M, G115D, G120-CU240B-E-2, G120-CU250S-2, G120D, G200, G220

Power unit: Inverter heatsink overheat

converter

Meaning: The power unit heatsink temperature has exceeded the permissible limit. - Insufficient ventilation or fan fault. - Overload. - Ambient temperature too high. - Pulse frequency too high.

Possible causes

Source: SINAMICS G110M P735; SINAMICS G115D P790; SINAMICS G120, control unit CU240B-2_CU240E-2 P760; SINAMICS G120, control unit CU250S-2 P1452; SINAMICS G120D control unit CU240D- 2_CU250D- 2 P914; SINAMICS G200 Basic converter P621; SINAMICS G220 converter P1443

Series: G120-CU230P-2, G120P-Cabinet

Converter overheat

converter

Meaning:

Possible causes

Source: Converter SINAMICS G120, equipped with control unit CU230P-2 P496; SINAMICS G120P Cabinet P514

Series: G120C

"Overtemperature heat sink AC inverter"

converter

Meaning:

Possible causes

Source: SINAMICS G120C P615

Series: G120X

Heatsink overheat

converter

Meaning:

Possible causes

Source: SINAMICS G120X converter P1438

Series: G120XA

Power unit: Inverter heatsink overheat

converter

Meaning:

Possible causes

Source: SINAMICS G120XA PN converter P1313

Series: G130-G150

inverter heatsink

converter

Meaning:

Possible causes

Source: G150 P737

Series: G210, G210X, S220

"heat sink AC inverter"

converter

Meaning:

Possible causes

Source: SINAMICS G210 converter P934; SINAMICS G210X converter P801; SINAMICS S220 converter P1942

Series: S110

inverter heatsink

servo drive

Meaning:

Possible causes

Source: SINAMICS S110 P886

Series: S200

Power unit: Inverter heatsink overheat

servo drive

Meaning: The power unit heatsink temperature has exceeded the permissible limit. - Insufficient ventilation or fan fault. - Overload. - Ambient temperature too high. - Pulse frequency too high.

Possible causes

Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P550

Series: S210

Power unit: Inverter heatsink overheat

servo drive

Meaning: The power unit heatsink temperature exceeded the permissible limit. - Insufficient ventilation or fan fault. - Overload. - Ambient temperature too high. - Pulse frequency too high.

Possible causes

Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P901

Series: V90

Drive heatsink overheat

servo drive

Meaning: The power unit heatsink temperature has exceeded the permissible limit. Insufficient ventilation or fan fault. Overload. Ambient temperature too high. Pulse frequency too high. Reduce the pulse frequency if it exceeds the rated pulse frequency.

Possible causes

Source: SINAMICS V90 PROFINET, SIMOTICS S-1FL6 Operating Instructions P382