Siemens F30004 fault code meaning
Siemens / F30004
Series: DCM-6RA80
Power unit: Inverter heatsink overheat
DC drive
Meaning: The power unit heatsink temperature exceeded the permissible limit. - Insufficient ventilation or fan fault. - Overload. - Ambient temperature too high. - Pulse frequency too high.
Possible causes
Source: SINAMICS DCM, Parameter Manual, Firmware Version 1.5 SP2 (based on 5.1 SP2) P1035
Series: G110M, G115D, G120-CU240B-E-2, G120-CU250S-2, G120D, G200, G220
Power unit: Inverter heatsink overheat
converter
Meaning: The power unit heatsink temperature has exceeded the permissible limit. - Insufficient ventilation or fan fault. - Overload. - Ambient temperature too high. - Pulse frequency too high.
Possible causes
Source: SINAMICS G110M P735; SINAMICS G115D P790; SINAMICS G120, control unit CU240B-2_CU240E-2 P760; SINAMICS G120, control unit CU250S-2 P1452; SINAMICS G120D control unit CU240D- 2_CU250D- 2 P914; SINAMICS G200 Basic converter P621; SINAMICS G220 converter P1443
Series: G120-CU230P-2, G120P-Cabinet
Converter overheat
converter
Meaning:
Possible causes
Source: Converter SINAMICS G120, equipped with control unit CU230P-2 P496; SINAMICS G120P Cabinet P514
Series: G120C
"Overtemperature heat sink AC inverter"
converter
Meaning:
Possible causes
Source: SINAMICS G120C P615
Series: G120X
Heatsink overheat
converter
Meaning:
Possible causes
Source: SINAMICS G120X converter P1438
Series: G120XA
Power unit: Inverter heatsink overheat
converter
Meaning:
Possible causes
Source: SINAMICS G120XA PN converter P1313
Series: G130-G150
inverter heatsink
converter
Meaning:
Possible causes
Source: G150 P737
Series: G210, G210X, S220
"heat sink AC inverter"
converter
Meaning:
Possible causes
Source: SINAMICS G210 converter P934; SINAMICS G210X converter P801; SINAMICS S220 converter P1942
Series: S110
inverter heatsink
servo drive
Meaning:
Possible causes
Source: SINAMICS S110 P886
Series: S200
Power unit: Inverter heatsink overheat
servo drive
Meaning: The power unit heatsink temperature has exceeded the permissible limit. - Insufficient ventilation or fan fault. - Overload. - Ambient temperature too high. - Pulse frequency too high.
Possible causes
Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P550
Series: S210
Power unit: Inverter heatsink overheat
servo drive
Meaning: The power unit heatsink temperature exceeded the permissible limit. - Insufficient ventilation or fan fault. - Overload. - Ambient temperature too high. - Pulse frequency too high.
Possible causes
Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P901
Series: V90
Drive heatsink overheat
servo drive
Meaning: The power unit heatsink temperature has exceeded the permissible limit. Insufficient ventilation or fan fault. Overload. Ambient temperature too high. Pulse frequency too high. Reduce the pulse frequency if it exceeds the rated pulse frequency.
Possible causes
Source: SINAMICS V90 PROFINET, SIMOTICS S-1FL6 Operating Instructions P382