Siemens F30002 fault code meaning
Siemens / F30002
Series: G110M
DC bus overvoltage
converter
Meaning:
Possible causes
Source: SINAMICS G110M Converter P381
Series: G115D, G120-CU240B-E-2, G120D, G120XA
Power unit: DC bus overvoltage
converter
Meaning: The power unit detected overvoltage in the DC bus. - The motor is feeding back too much energy. - The power supply input voltage is too high. - Power supply phase interruption. - DC bus voltage control is disabled. - The dynamic response of the DC bus voltage controller is too large or too small.
Possible causes
Source: SINAMICS G115D P790; SINAMICS G120, Control Unit CU240B-2_CU240E-2 P760; SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P914; SINAMICS G120XA PN Converter P1313
Series: G120-CU230P-2, G120C, G120P-Cabinet
DC bus overvoltage
converter
Meaning:
Possible causes
Source: Converter SINAMICS G120, equipped with control unit CU230P-2 P496; converter SINAMICS G120C P408; SINAMICS G120P Cabinet P514
Series: G120-CU250S-2
Power unit: DC bus overvoltage
converter
Meaning: The power unit detected DC bus overvoltage. - Excessive energy fed back by the motor. - Equipment input voltage too high. - During operation with a voltage monitoring module (VSM), the phase assignment L1, L2, L3 on VSM differs from the phase assignment on the power unit. - Power supply phase interruption.
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1451
Series: G130-G150, S120-S150
"DC link overvoltage"
converter
Meaning:
Possible causes
Source: SINAMICS G130_G150 P1373; SINAMICS S120_S150 P2394
Series: G200, G210, G210X
Power unit: DC bus overvoltage
converter
Meaning: The power unit detected overvoltage in the DC bus. - Excessive regenerative energy from the motor. - Equipment input voltage too high. - During operation with a voltage monitoring module (VSM), the phase assignments L1, L2, and L3 on VSM differ from those on the power unit. - Mains phase interruption. - Ground fault. - Short circuit.
Possible causes
Source: SINAMICS G200 Converter P746; SINAMICS G210 Converter P1185; SINAMICS G210X Converter P1011
Series: G220, S220
"Power unit: DC link voltage overvoltage"
converter
Meaning:
Possible causes
Source: SINAMICS G220 Converter P1146; SINAMICS S220 Converter P1969
Series: S200
Drive: DC bus overvoltage
servo drive
Meaning:
Possible causes
Source: SINAMICS S200 Spindle Drive P410
Series: S210
Drive: DC bus overvoltage
servo drive
Meaning: The drive has detected DC bus overvoltage. - Excessive energy regeneration from the motor. - Equipment input voltage too high. - Supply phase interruption.
Possible causes
Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1348
Series: V90
DC bus overvoltage
servo drive
Meaning: The power unit has detected DC bus overvoltage. Excessive energy fed back by the motor. Equipment input voltage too high. Power supply phase interruption.
Possible causes
Source: SINAMICS V90 PROFINET, SIMOTICS S-1FL6 Operating Instructions P381