Infeed: Power unit hardware current limit activated too frequently
converter
Meaning: %1 bin Model: SLM Component: Power unit Broadcast: Local Reaction: OFF2 Acknowledgment: Immediate Cause: Hardware current limiting responds too frequently in the individual phases (see A29031, A29032, A29033). The permissible number of limit exceedances depends on the power unit category and type. Setting requirements: - Load too large. - Incorrect closed-loop control parameter settings. - Line reactor missing or incorrect type. - Incorrect voltage monitoring module connection. - Power unit damaged.
Possible causes
Source: SINAMICS S220 converter P2412