Siemens F1911 fault code meaning
Siemens / F1911
Series: V90
PROFIdrive: Isochronous cycle fault
servo drive
Meaning: During cyclic operation, the global control telegram failed to synchronize multiple DP clock cycles, or the time window defined in the telegram parameters was violated for multiple consecutive DP clock cycles (see bus cycle time Tdp and Tpllw).
Possible causes
Source: SINAMICS V90 PROFINET, SIMOTICS S-1FL6 Operating Instructions P370