Siemens F07977 fault code meaning

Siemens / F07977

Series: G200, G210, G210X, G220, S220

EOM and Safety Integrated (SI are not supported

converter

Meaning: EOM and one Safety Integrated Function have been activated simultaneously. The drive does not support simultaneous use of these two functions. Note: EOM: Emergency Operation Mode (emergency mode)

Possible causes

Source: SINAMICS G200 converter P732; SINAMICS G210 converter P1170; SINAMICS G210X converter P997; SINAMICS G220 converter P1391; SINAMICS S220 converter P2382