Siemens F07955 fault code meaning
Siemens / F07955
Series: G120-CU250S-2
Drive: Motor has been changed
converter
Meaning: There is a mismatch between the current motor code number with DRIVE-CLiQ and the stored number.
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1425
Series: G130-G150, S120-S150
Drive: Motor has been changed
converter
Meaning: The current motor code number with DRIVE-CLiQ does not match the stored number. The code number for the bearing, gearbox, or holding brake does not match the stored number.
Possible causes
Source: SINAMICS G130_G150 P1679; SINAMICS S120_S150 P2832
Series: G210, G220
Drive: Motor has been changed
converter
Meaning: There is a mismatch between the current motor code with DRIVE-CLiQ and the stored code. There is a mismatch between the bearing, gearbox or holding brake code and the stored code.
Possible causes
Source: SINAMICS G210 converter P1162; SINAMICS G220 converter P1383
Series: G210X
Drive: Motor has been changed
converter
Meaning:
Possible causes
Source: SINAMICS G210X Converter P991
Series: S110
Drive: Motor has been changed
servo drive
Meaning: There is a mismatch between the current motor code number with DRIVE-CLiQ and the stored number.
Possible causes
Source: SINAMICS S110 P1058
Series: S200
Drive: Motor has been changed
servo drive
Meaning: The bearing, gearbox, or holding brake code and the stored code mismatch.
Possible causes
Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P544
Series: S210
Drive: Motor has been changed
servo drive
Meaning: The current motor code number with DRIVE-CLiQ does not match the stored code number. Alternatively, the codes for the bearings, gearbox, and holding brake do not match the stored codes.
Possible causes
Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1342