Siemens F07914 fault code meaning
Siemens / F07914
Series: G120-CU250S-2, G130-G150, S120-S150
Magnetic flux out of tolerance
converter
Meaning: The difference between the actual flux and its setpoint exceeds the tolerance: absolute value of (r0084 - r1598) > p3204 + p3205. The error is cleared when the absolute value of (r0084 - r1598) < p3204. The fault message can only be acknowledged after delay time p3206 has elapsed.
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1419; SINAMICS G130_G150 P1671; SINAMICS S120_S150 P2824
Series: S110
Magnetic flux out of tolerance
servo drive
Meaning: The difference between the actual flux and its setpoint exceeds the tolerance: absolute value of (r0084 - r1598) > p3204 + p3205. The error is cleared when the absolute value of (r0084 - r1598) < p3204. The fault message can only be acknowledged after delay time p3206 has elapsed.
Possible causes
Source: SINAMICS S110 P1054