Siemens F07901 fault code meaning

Siemens / F07901

Series: G110M, G115D, G120-CU240B-E-2, G120-CU250S-2, G120D, G120X, G120XA, G130-G150, S120-S150

Drive: Motor speed too high

converter

Meaning: The maximum permissible positive or negative speed has been exceeded. The maximum permissible positive speed is calculated as follows: minimum(p1082, CI: p1085) + p2162. The maximum permissible negative speed is calculated as follows: maximum(-p1082, CI: p1088) - p2162.

Possible causes

Source: SINAMICS G110M P715; SINAMICS G115D P773; SINAMICS G120, Control Unit CU240B-2_CU240E-2 P744; SINAMICS G120, Control Unit CU250S-2 P1414; SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P895; SINAMICS G120X Converter P1388; SINAMICS G120XA PN Converter P1299; SINAMICS G130_G150 P1666; SINAMICS S120_S150 P2817

Series: G120-CU230P-2, G120P-Cabinet

Motor overspeed

converter

Meaning:

Possible causes

Source: Converter SINAMICS G120, equipped with control unit CU230P-2 P494; SINAMICS G120P Cabinet P512

Series: G120C

Drive: Motor speed too high

converter

Meaning: The maximum permissible positive or negative speed was exceeded. The maximum permissible positive speed is calculated as follows: Minimum (p1082). The maximum permissible negative speed is calculated as follows: Maximum (-p1082).

Possible causes

Source: SINAMICS G120C P687

Series: G210X

Drive: Motor speed too high

converter

Meaning: The maximum permissible positive or negative speed has been exceeded. The maximum permissible positive speed is calculated as: minimum (p1082, c1085) + p2162. The maximum permissible negative speed is calculated as: maximum (-p1082, c1088) - p2162.

Possible causes

Source: SINAMICS G210X converter P984

Series: S200

Drive: Motor speed too high

servo drive

Meaning: The maximum permissible positive or negative speed has been exceeded. The maximum permissible positive speed is calculated as: minimum (p1082, p1083, p29072) + p2162. The maximum permissible negative speed is calculated as: maximum (-p1082, p1086, p29073) - p2162.

Possible causes

Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P542

Series: S210

Drive: Motor speed too high

servo drive

Meaning: The maximum permissible positive or negative speed (p1082) has been exceeded.

Possible causes