Siemens F07894 fault code meaning

Siemens / F07894

Series: G110M

Drive: Pump/fan stall monitoring

converter

Meaning: Load monitoring is configured for a pump or fan (p2193 = 4, 5). Monitoring has detected a locked rotor in the pump/fan. The set locked rotor torque threshold (p2168) may be too low (e.g., during a heavy-load start). See: p2165 (Locked rotor monitoring upper limit), p2168 (Locked rotor monitoring torque threshold), p2181 (Load monitoring response), p2193 (Load monitoring configuration).

Possible causes

Source: SINAMICS G110M P714

Series: G115D, G120-CU240B-E-2

Drive: Pump/fan stall monitoring

converter

Meaning: Load monitoring is configured for a pump or fan (p2193 = 4, 5). Monitoring has detected a locked rotor in the pump/fan. The configured locked rotor torque threshold (p2168) may be too low (e.g., for a start under heavy load). See also: p2165 (locked rotor monitoring upper limit), p2168 (torque threshold for locked rotor monitoring), p2181 (load monitoring response), p2193 (load monitoring configuration).

Possible causes

Source: SINAMICS G115D P772;SINAMICS G120 Control Unit CU240B- 2_CU240E- 2 P850

Series: G120-CU230P-2

Load monitoring: Pump/fan stalled

converter

Meaning:

Possible causes

Source: Converter SINAMICS G120, equipped with control unit CU230P-2 P494

Series: G120-CU250S-2

Drive: Pump/fan stall monitoring

converter

Meaning: Load monitoring is configured for a pump or fan (p2193 = 4, 5). Monitoring has detected a locked rotor in the pump/fan. The locked rotor torque threshold setting (p2168) may be too low (e.g., for a start under heavy load). See: p2181 (Load monitoring response), p2193 (Load monitoring configuration).

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1043

Series: G120C

Drive: Pump/fan stall monitoring

converter

Meaning: Load monitoring is configured for a pump or fan (p2193 = 4, 5). Monitoring has detected a locked rotor in the pump/fan. The locked rotor torque threshold setting (p2168) may be too low (e.g., during a start under heavy load). See also: p2165 (Locked rotor monitoring upper limit), p2168 (Torque threshold for locked rotor monitoring).

Possible causes

Source: SINAMICS G120C P686

Series: G120D

Drive: Pump/fan stall monitoring

converter

Meaning:

Possible causes

Source: SINAMICS G120D control unit CU240D- 2_CU250D- 2 P894

Series: G120X, G120XA

Drive: Pump/fan stall monitoring

converter

Meaning: Load monitoring is configured for a pump or fan (p2193 = 4, 5). Monitoring has detected a locked rotor in the pump/fan. The locked rotor torque threshold setting (p2168) may be too low (e.g., during a start under heavy load). See also: p2165, p2168, p2181, p2193.

Possible causes

Source: SINAMICS G120X converter P1387; SINAMICS G120XA PN converter P1298

Series: G210, G210X, S220

Drive: Pump/fan stall monitoring

converter

Meaning: Load monitoring is configured for a pump or fan (p2193 = 4, 5). Monitoring has detected a locked rotor in the pump/fan. The configured locked rotor torque threshold (p2168) may be too low (for example, during a start under heavy load). See also: p2165 (Locked rotor monitoring upper limit), p2168 (Torque threshold for locked rotor monitoring), p2181 (Load monitoring response), p2193 (Load monitoring configuration).

Possible causes

Source: SINAMICS G210 converter P1154; SINAMICS G210X converter P982; SINAMICS S220 converter P2351

Series: G220

Drive: Pump/fan stall monitoring

converter

Meaning: Load monitoring is configured for a pump or fan (p2193 = 4, 5). Monitoring has detected a locked rotor in the pump/fan. The locked rotor torque threshold setting (p2168) may be too low (for example, during a start under heavy load). See also: p2165, p2168, p2181, p2193

Possible causes

Source: SINAMICS G220 Converter P1370