Siemens F07841 fault code meaning
Siemens / F07841
Series: G120-CU250S-2, S120-S150
Drive: Infeed operation canceled
converter
Meaning: The "Infeed running" signal was withdrawn during operation. - The BI connection for the "Infeed running" signal is incorrect or missing (p0864). - The infeed enable signal was interrupted. - The infeed withdrew the "Infeed running" signal due to this fault.
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1411; SINAMICS S120_S150 P2812
Series: G130-G150
Drive: Infeed operation canceled
converter
Meaning:
Possible causes
Source: SINAMICS G130_G150 P1662
Series: G220, S220
Drive: Infeed operation canceled
converter
Meaning: The "Infeed running" signal was withdrawn during operation. - The interconnection of the binector input for the "Infeed running" signal is incorrect or missing (c0864). - The infeed enable has been withdrawn. - The infeed has withdrawn the "Infeed running" signal due to this fault.
Possible causes
Source: SINAMICS G220 Converter P1368; SINAMICS S220 Converter P2348