Siemens F07810 fault code meaning
Siemens / F07810
Series: G110M, G120-CU240B-E-2, G120-CU250S-2
Drive: No rated data for power unit EEPROM
converter
Meaning: No rated data is stored in power unit EEPROM. See: p0205 (Power unit application), r0206 (Power unit rated power), r0207 (Power unit rated current), r0208 (Power unit rated input voltage), r0209 (Power unit maximum current).
Possible causes
Source: SINAMICS G110M P712; SINAMICS G120, Control Unit CU240B-2_CU240E-2 P742; SINAMICS G120, Control Unit CU250S-2 P995
Series: G115D, G120C, G120D
Drive: No rated data for power unit EEPROM
converter
Meaning: No rated data is stored in power unit EEPROM. See also: p0205 (Power unit application), r0206 (Power unit rated power), r0207 (Power unit rated current), r0208 (Power unit rated input voltage), r0209 (Power unit maximum current)
Possible causes
Source: SINAMICS G115D P770; SINAMICS G120C P685; SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P892
Series: G120X, G120XA
Drive: No rated data for power unit EEPROM
converter
Meaning: No rated data is stored in power unit EEPROM. See also: p0205, r0206, r0207, r0208, r0209
Possible causes
Source: SINAMICS G120X Converter P1385; SINAMICS G120XA PN Converter P1296
Series: G130-G150
Drive: No rated data for power unit EEPROM
converter
Meaning: No rated data is stored in power unit EEPROM. See also: p0205 (power unit application), r0206 (power unit rated power), r0207 (power unit rated current), r0208 (power unit rated input voltage), r0209 (power unit maximum current).
Possible causes
Source: SINAMICS G130_G150 P1659
Series: S110
Drive: No rated data for power unit EEPROM
servo drive
Meaning: No rated data is stored in power unit EEPROM. See: r0206 (Power unit rated power), r0207 (Power unit rated current), r0208 (Power unit rated input voltage), r0209 (Power unit maximum current).
Possible causes
Source: SINAMICS S110 P1047
Series: S120-S150
Drive: No rated data for power unit EEPROM
converter
Meaning: No rated data is stored in power unit EEPROM. See also: p0205, r0206 (power unit rated power), r0207 (power unit rated current), r0208 (power unit rated input voltage), r0209 (power unit maximum current)
Possible causes
Source: SINAMICS S120_S150 P2808
Series: S200
Drive: No rated data for power unit EEPROM
servo drive
Meaning: No rated data is stored in power unit EEPROM. See also: r0208 (Rated mains voltage of the power unit).
Possible causes
Source: SINAMICS S200 Spindle drive P402
Series: S220
Drive: No rated data for power unit EEPROM
converter
Meaning: No rated data is stored in power unit EEPROM. See also: r0206, r0207, r0208, r0209
Possible causes
Source: SINAMICS S220 Converter P2346