Siemens F07802 fault code meaning
Siemens / F07802
Series: G110M, G115D, G120-CU240B-E-2, G120-CU250S-2, G120C, G120D
Drive: Infeed or power unit not ready
converter
Meaning: The infeed or drive did not return a ready signal after the internal switch-on command. - The monitoring time is too short. - No DC bus voltage is present. - The infeed or drive to which the component belongs has a fault. - The input voltage setting is incorrect.
Possible causes
Source: SINAMICS G110M P711; SINAMICS G115D P769; SINAMICS G120, Control Unit CU240B-2_CU240E-2 P741; SINAMICS G120, Control Unit CU250S-2 P1409; SINAMICS G120C P684; SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P891
Series: G120X
Drive: Infeed or power unit not ready
converter
Meaning: The infeed or drive did not return a ready signal after the internal switch-on command. - The monitoring time is too short. - No DC bus voltage is present. - The infeed or drive associated with the component has a fault. - The input voltage setting is incorrect.
Possible causes
Source: SINAMICS G120X converter P1384
Series: G120XA
Drive: Infeed or power unit not ready
converter
Meaning: The infeed or drive did not return a ready signal after the internal switch-on command. - The monitoring time is too short. - No DC bus voltage is present. - The infeed or drive associated with the component has a fault. - The input voltage setting is incorrect. Alarms, faults and system messages 10.6 List of fault codes and alarm codes SINAMICS G120XA converter 934 Operating Instructions, 12/2019, FW V1.01, A5E44751205F AD
Possible causes
Source: SINAMICS G120XA converter Operating Instructions P936
Series: G130-G150
Drive: Infeed or power unit not ready
converter
Meaning:
Possible causes
Source: G150 P879
Series: S110
Drive: Infeed or power unit not ready
servo drive
Meaning: The infeed or drive did not return a ready signal after the internal switch-on command. - The monitoring time is too short. - No DC bus voltage is present. - The infeed or drive to which the component belongs has a fault. - The input voltage setting is incorrect.
Possible causes
Source: SINAMICS S110 P1046
Series: S200
Drive: Infeed not ready
servo drive
Meaning: The drive did not return "Ready" feedback after the internal switch-on command. - The DC bus voltage is absent, or the jumper is not inserted in X1/X4. - The input voltage setting is incorrect. - The drive is damaged.
Possible causes
Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P540
Series: S210
Drive: Infeed not ready
servo drive
Meaning: The drive did not return a ready signal after the internal switch-on command. - No DC bus voltage is present. - The drive is damaged. - The input voltage setting is incorrect.
Possible causes
Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P892