Siemens F07802 fault code meaning

Siemens / F07802

Series: G110M, G115D, G120-CU240B-E-2, G120-CU250S-2, G120C, G120D

Drive: Infeed or power unit not ready

converter

Meaning: The infeed or drive did not return a ready signal after the internal switch-on command. - The monitoring time is too short. - No DC bus voltage is present. - The infeed or drive to which the component belongs has a fault. - The input voltage setting is incorrect.

Possible causes

Source: SINAMICS G110M P711; SINAMICS G115D P769; SINAMICS G120, Control Unit CU240B-2_CU240E-2 P741; SINAMICS G120, Control Unit CU250S-2 P1409; SINAMICS G120C P684; SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P891

Series: G120X

Drive: Infeed or power unit not ready

converter

Meaning: The infeed or drive did not return a ready signal after the internal switch-on command. - The monitoring time is too short. - No DC bus voltage is present. - The infeed or drive associated with the component has a fault. - The input voltage setting is incorrect.

Possible causes

Source: SINAMICS G120X converter P1384

Series: G120XA

Drive: Infeed or power unit not ready

converter

Meaning: The infeed or drive did not return a ready signal after the internal switch-on command. - The monitoring time is too short. - No DC bus voltage is present. - The infeed or drive associated with the component has a fault. - The input voltage setting is incorrect. Alarms, faults and system messages 10.6 List of fault codes and alarm codes SINAMICS G120XA converter 934 Operating Instructions, 12/2019, FW V1.01, A5E44751205F AD

Possible causes

Source: SINAMICS G120XA converter Operating Instructions P936

Series: G130-G150

Drive: Infeed or power unit not ready

converter

Meaning:

Possible causes

Source: G150 P879

Series: S110

Drive: Infeed or power unit not ready

servo drive

Meaning: The infeed or drive did not return a ready signal after the internal switch-on command. - The monitoring time is too short. - No DC bus voltage is present. - The infeed or drive to which the component belongs has a fault. - The input voltage setting is incorrect.

Possible causes

Source: SINAMICS S110 P1046

Series: S200

Drive: Infeed not ready

servo drive

Meaning: The drive did not return "Ready" feedback after the internal switch-on command. - The DC bus voltage is absent, or the jumper is not inserted in X1/X4. - The input voltage setting is incorrect. - The drive is damaged.

Possible causes

Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P540

Series: S210

Drive: Infeed not ready

servo drive

Meaning: The drive did not return a ready signal after the internal switch-on command. - No DC bus voltage is present. - The drive is damaged. - The input voltage setting is incorrect.

Possible causes

Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P892