Siemens F07800 fault code meaning

Siemens / F07800

Series: G110M, G115D, G120C, G120X

Drive: No power unit

converter

Meaning: The power unit parameters cannot be read, or no parameters are stored in the power unit.

Possible causes

Source: SINAMICS G110M P710; SINAMICS G115D P768; SINAMICS G120C P684; SINAMICS G120X Converter P1383

Series: G120-CU240B-E-2

Drive: No power unit

converter

Meaning: The power unit parameters cannot be read, or no parameters are stored in the power unit. The connection between the control unit and the power unit is interrupted or damaged. Note: This fault occurs if an incorrect topology is selected in the commissioning software and this parameter configuration is loaded into the control unit. See: r0200 (Power unit current code number).

Possible causes

Source: SINAMICS G120 Control Unit CU240B_E-2 P671

Series: G120-CU250S-2, G130-G150, S120-S150

Drive: No power unit

converter

Meaning: The power unit parameters cannot be read, or no parameters are stored in the power unit. The DRIVE-CLiQ cable between the control unit and the power unit may be interrupted or damaged.

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1408; SINAMICS G130_G150 P1656; SINAMICS S120_S150 P2805

Series: G120D

Drive: No power unit

converter

Meaning:

Possible causes

Source: SINAMICS G120D control unit CU240D- 2_CU250D- 2 P890

Series: G120XA

Drive: No power unit

converter

Meaning: The power unit parameters cannot be read, or the power unit has not stored any parameters.

Possible causes

Source: SINAMICS G120XA PN converter P1294

Series: G200

Drive: No power unit

converter

Meaning: The power unit parameters cannot be read, or no parameters are stored in the power unit. Note: This fault occurs if an incorrect topology is selected in the commissioning tool and this parameter configuration is loaded into the converter.

Possible causes

Source: SINAMICS G200 Basic converter P594

Series: G210X, G220

Drive: No power unit

converter

Meaning: The power unit parameters cannot be read, or no parameters are stored in the power unit. Note: This fault occurs if an incorrect topology is selected in the commissioning tool and this parameter configuration is loaded into the converter. See also: r0200 (Current power unit code).

Possible causes

Source: SINAMICS G210X Converter P978; SINAMICS G220 Converter P1365

Series: S220

Drive: No power unit

converter

Meaning: The power unit parameters cannot be read, or no parameters are stored in the power unit. Note: This fault occurs if an incorrect topology is selected in the commissioning tool and this parameter configuration is loaded into the control unit. See also: r0200 (Current power unit code)

Possible causes

Source: SINAMICS S220 Converter P2343