Siemens F07800 fault code meaning
Siemens / F07800
Series: G110M, G115D, G120C, G120X
Drive: No power unit
converter
Meaning: The power unit parameters cannot be read, or no parameters are stored in the power unit.
Possible causes
Source: SINAMICS G110M P710; SINAMICS G115D P768; SINAMICS G120C P684; SINAMICS G120X Converter P1383
Series: G120-CU240B-E-2
Drive: No power unit
converter
Meaning: The power unit parameters cannot be read, or no parameters are stored in the power unit. The connection between the control unit and the power unit is interrupted or damaged. Note: This fault occurs if an incorrect topology is selected in the commissioning software and this parameter configuration is loaded into the control unit. See: r0200 (Power unit current code number).
Possible causes
Source: SINAMICS G120 Control Unit CU240B_E-2 P671
Series: G120-CU250S-2, G130-G150, S120-S150
Drive: No power unit
converter
Meaning: The power unit parameters cannot be read, or no parameters are stored in the power unit. The DRIVE-CLiQ cable between the control unit and the power unit may be interrupted or damaged.
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1408; SINAMICS G130_G150 P1656; SINAMICS S120_S150 P2805
Series: G120D
Drive: No power unit
converter
Meaning:
Possible causes
Source: SINAMICS G120D control unit CU240D- 2_CU250D- 2 P890
Series: G120XA
Drive: No power unit
converter
Meaning: The power unit parameters cannot be read, or the power unit has not stored any parameters.
Possible causes
Source: SINAMICS G120XA PN converter P1294
Series: G200
Drive: No power unit
converter
Meaning: The power unit parameters cannot be read, or no parameters are stored in the power unit. Note: This fault occurs if an incorrect topology is selected in the commissioning tool and this parameter configuration is loaded into the converter.
Possible causes
Source: SINAMICS G200 Basic converter P594
Series: G210X, G220
Drive: No power unit
converter
Meaning: The power unit parameters cannot be read, or no parameters are stored in the power unit. Note: This fault occurs if an incorrect topology is selected in the commissioning tool and this parameter configuration is loaded into the converter. See also: r0200 (Current power unit code).
Possible causes
Source: SINAMICS G210X Converter P978; SINAMICS G220 Converter P1365
Series: S220
Drive: No power unit
converter
Meaning: The power unit parameters cannot be read, or no parameters are stored in the power unit. Note: This fault occurs if an incorrect topology is selected in the commissioning tool and this parameter configuration is loaded into the control unit. See also: r0200 (Current power unit code)
Possible causes
Source: SINAMICS S220 Converter P2343