Siemens F07599 fault code meaning
Siemens / F07599
Series: G120-CU250S-2
Encoder 1: Cannot perform calibration
converter
Meaning: The product of the factor for converting the absolute position (r0483 or r2723) from increments to length units (LU) and the maximum encoder value exceeds the range specified for the actual position value (-2147483648 ... 2147483647).
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1407
Series: G120D
Encoder 1: Cannot perform calibration
converter
Meaning: The product of the maximum encoder value and the factor for converting the absolute position (r0483 or r2723) from increments to length units (LU) exceeds the value range for representing the actual position (-2147483648 ... 2147483647).
Possible causes
Source: SINAMICS G120D control unit CU240D- 2_CU250D- 2 P890
Series: S110
Encoder 1: Cannot perform calibration
servo drive
Meaning: The product of the maximum encoder value and the factor for converting the absolute position (r0483 or r2723) from increments to length units (LU) exceeds the value range for representing the actual position (-2147483648 ... 2147483647).
Possible causes
Source: SINAMICS S110 P1044