Siemens F07562 fault code meaning

Siemens / F07562

Series: DCM-6RA80

Drive encoder: Position tracking cannot be performed with the incremental encoder

DC drive

Meaning: %1, Component number: %2, Encoder data set: %3 Message class: Parameter setting/configuration/commissioning error (18) Drive object: DC_CTRL, DC_CTRL_R, DC_CTRL_R_S, DC_CTRL_S Component: None Propagation: GLOBAL Reaction: OFF2 (IASC/DCBRK, OFF1, OFF3, STOP2, None) Acknowledgment: Immediately (power-on) Cause: The requested incremental encoder position tracking is not supported.

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1019

Series: G120-CU250S-2

Drive encoder: Position tracking cannot be performed with the incremental encoder

converter

Meaning: %1, Component number: %2, Encoder data set: %3 Drive object: All objects. Reaction: OFF2 (IASC/DCBRK, OFF1, OFF3, STOP1, STOP2, None). Acknowledgment: Immediately (power-on). Cause: The requested incremental encoder position tracking is not supported.

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1401

Series: G130-G150

Drive encoder: Position tracking cannot be performed with the incremental encoder

converter

Meaning: %1, component number: %2, encoder data set: %3 Message class: Parameter setting/configuration/commissioning error (18) Drive object: B_INF, ENC, VECTOR_G Component: None Broadcast: GLOBAL Reaction: Vector: OFF2 (IASC/DCBRK, OFF1, OFF3, STOP2, none) Infeed: OFF2 (OFF1, none) Acknowledgment: Immediate (power-on)

Possible causes

Source: SINAMICS G130_G150 P1643

Series: G210

Drive encoder: Position tracking cannot be performed with the incremental encoder

converter

Meaning: %1, Component number: %2, Encoder data set: %3 Component: None Broadcast: Global Response: OFF2 (IASC/DCBRK, OFF1, OFF3, STOP2, None) Acknowledgment: Immediate Cause: The requested incremental encoder position tracking is not supported.

Possible causes

Source: SINAMICS G210 converter P1140

Series: S110

Drive encoder: Position tracking cannot be performed with the incremental encoder

servo drive

Meaning: %1, component number: %2, encoder data set: %3. Drive object: SERVO_S110-CAN, SERVO_S110-DP, SERVO_S110-PN. Reaction: OFF2 (IASC/ DC brake, OFF1, OFF3, STOP1, STOP2, none). Acknowledgment: Immediate (power-on). Cause: The requested incremental encoder position tracking is not supported.

Possible causes

Source: SINAMICS S110 P1038

Series: S220

Drive encoder: Position tracking cannot be performed with the incremental encoder

converter

Meaning: %1, Component number: %2, Encoder data set: %3 Model: Servo, Vector Component: None Broadcast: Global Reaction: OFF2 (IASC/DCBRK, OFF1, OFF3, STOP2, None) Acknowledgment: Immediate Faults and alarms 5.5 List of faults and alarms SINAMICS S220 Converter 2328 Parameter Manual, 08/2026, FW V6.7, A5E53307549F AB

Possible causes

Source: SINAMICS S220 Converter P2330