Siemens F07556 fault code meaning
Siemens / F07556
Series: DCM-6RA80
Measuring gearbox: Position tracking exceeded the maximum actual value
DC drive
Meaning: The drive/encoder detected a maximum actual absolute position value (r0483) in the configured position tracking of the measuring gearbox that cannot be represented in 32 bits. Maximum value: p0408 * p0412 * 2^p0419
Possible causes
Source: SINAMICS DCM, Parameter Manual, Firmware Version 1.5 SP2 (based on 5.1 SP2) P1018
Series: G120-CU250S-2, G130-G150, S120-S150
Measuring gearbox: Position tracking exceeded the maximum actual value
converter
Meaning: The drive/encoder has detected a maximum absolute actual position value (r0483) in the configured position tracking for the measuring gearbox that cannot be represented in 32 bits. Maximum value: p0408 * p0412 * 2^p0419
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1400; SINAMICS G130_G150 P1642; SINAMICS S120_S150 P2788