Siemens F07518 fault code meaning
Siemens / F07518
Series: DCM-6RA80
Drive: Incorrect parameter settings for motor data set changeover
DC drive
Meaning: An incorrect parameter setting was detected in one of two motor data sets. Parameters r0313 (calculated from p0314, p0310, and p0311), r0315, and p1982 may have different values only if these motor data sets are assigned to different motors. Assignment to the motor or contactor is made via p0827. Switching between motor data sets is not possible.
Possible causes
Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1014
Series: G120-CU250S-2
Drive: Incorrect parameter settings for motor data set changeover
converter
Meaning: An incorrect parameter setting has been detected in one of the two motor data sets. Parameters r0313 (calculated from p0314, p0310, and p0311), r0315, and p1982 may have different values only if these motor data sets are assigned to different motors. Assignment to a motor or contactor is performed via p0827. Switching between the motor data sets is not possible.
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1397
Series: G130-G150, S120-S150
Drive: Incorrect parameter settings for motor data set changeover
converter
Meaning: An incorrect parameter setting was detected in one of the two motor data sets. Parameters r0313 (calculated from p0314, p0310, and p0311), r0315, and p1982 may have different values only if these motor data sets are assigned to different motors. Assignment to motors or contactors is performed via p0827. Switching between motor data sets is not possible.
Possible causes
Source: SINAMICS G130_G150 P1637; SINAMICS S120_S150 P2782
Series: G200
Drive: Incorrect parameter settings for motor data set changeover
converter
Meaning: An incorrect parameter setting was detected in one of the two motor data sets. Parameter r0313 (calculated from p0314, p0310, and p0311) may have different values only if these motor data sets are assigned to different motors. Switching between the motor data sets is not possible.
Possible causes
Source: SINAMICS G200 Basic converter P593
Series: G210
Drive: Incorrect parameter settings for motor data set changeover
converter
Meaning:
Possible causes
Source: SINAMICS G210 converter P1134
Series: G210X
Drive: Incorrect parameter settings for motor data set changeover
converter
Meaning: An incorrect parameter setting was detected in two motor data sets. Parameters r0313 (calculated from p0314, p0310, and p0311) and p1982 may have different values only if these motor data sets are assigned to different motors. Switching between the motor data sets is not possible.
Possible causes
Source: SINAMICS G210X Converter P977
Series: S110
Drive: Incorrect parameter settings for motor data set changeover
servo drive
Meaning: An incorrect parameter setting was detected in one of the two motor data sets. Parameters r0313 (calculated from p0314, p0310, and p0311), r0315, and p1982 may have different values only if these motor data sets are assigned to different motors. Assignment to motors or contactors is performed via p0827. Switching between motor data sets is not possible.
Possible causes
Source: SINAMICS S110 P1033
Series: S220
Drive: Incorrect parameter settings for motor data set changeover
converter
Meaning: An incorrect parameter setting was found in one of two motor data sets. Parameters r0313 (calculated from p0314, p0310, and p0311), p0315, and p1982 may have different values only if these motor data sets are assigned to different motors. Assignment to a motor or contactor is made via p0827. Switching between motor data sets is not possible.
Possible causes
Source: SINAMICS S220 converter P2322