Siemens F07518 fault code meaning

Siemens / F07518

Series: DCM-6RA80

Drive: Incorrect parameter settings for motor data set changeover

DC drive

Meaning: An incorrect parameter setting was detected in one of two motor data sets. Parameters r0313 (calculated from p0314, p0310, and p0311), r0315, and p1982 may have different values only if these motor data sets are assigned to different motors. Assignment to the motor or contactor is made via p0827. Switching between motor data sets is not possible.

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1014

Series: G120-CU250S-2

Drive: Incorrect parameter settings for motor data set changeover

converter

Meaning: An incorrect parameter setting has been detected in one of the two motor data sets. Parameters r0313 (calculated from p0314, p0310, and p0311), r0315, and p1982 may have different values only if these motor data sets are assigned to different motors. Assignment to a motor or contactor is performed via p0827. Switching between the motor data sets is not possible.

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1397

Series: G130-G150, S120-S150

Drive: Incorrect parameter settings for motor data set changeover

converter

Meaning: An incorrect parameter setting was detected in one of the two motor data sets. Parameters r0313 (calculated from p0314, p0310, and p0311), r0315, and p1982 may have different values only if these motor data sets are assigned to different motors. Assignment to motors or contactors is performed via p0827. Switching between motor data sets is not possible.

Possible causes

Source: SINAMICS G130_G150 P1637; SINAMICS S120_S150 P2782

Series: G200

Drive: Incorrect parameter settings for motor data set changeover

converter

Meaning: An incorrect parameter setting was detected in one of the two motor data sets. Parameter r0313 (calculated from p0314, p0310, and p0311) may have different values only if these motor data sets are assigned to different motors. Switching between the motor data sets is not possible.

Possible causes

Source: SINAMICS G200 Basic converter P593

Series: G210

Drive: Incorrect parameter settings for motor data set changeover

converter

Meaning:

Possible causes

Source: SINAMICS G210 converter P1134

Series: G210X

Drive: Incorrect parameter settings for motor data set changeover

converter

Meaning: An incorrect parameter setting was detected in two motor data sets. Parameters r0313 (calculated from p0314, p0310, and p0311) and p1982 may have different values only if these motor data sets are assigned to different motors. Switching between the motor data sets is not possible.

Possible causes

Source: SINAMICS G210X Converter P977

Series: S110

Drive: Incorrect parameter settings for motor data set changeover

servo drive

Meaning: An incorrect parameter setting was detected in one of the two motor data sets. Parameters r0313 (calculated from p0314, p0310, and p0311), r0315, and p1982 may have different values only if these motor data sets are assigned to different motors. Assignment to motors or contactors is performed via p0827. Switching between motor data sets is not possible.

Possible causes

Source: SINAMICS S110 P1033

Series: S220

Drive: Incorrect parameter settings for motor data set changeover

converter

Meaning: An incorrect parameter setting was found in one of two motor data sets. Parameters r0313 (calculated from p0314, p0310, and p0311), p0315, and p1982 may have different values only if these motor data sets are assigned to different motors. Assignment to a motor or contactor is made via p0827. Switching between motor data sets is not possible.

Possible causes

Source: SINAMICS S220 converter P2322