Siemens F07509 fault code meaning

Siemens / F07509

Series: DCM-6RA80

Drive: Component assignment missing

DC drive

Meaning: A motor data set (MDS) or encoder data set (EDS) without a component number is assigned to the drive data set (DDS).

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1012

Series: G120-CU250S-2

Drive: Encoder assignment error

converter

Meaning: An encoder (p187 / p188) has been selected, but no physical interface (p468) has been assigned.

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1394

Series: G130-G150

Drive: Component assignment missing

converter

Meaning: A motor data set (MDS) or encoder data set (EDS) without a component number is assigned to the drive data set (DDS).

Possible causes

Source: SINAMICS G130_G150 P1634

Series: G200, G210X

Drive: Component assignment missing

converter

Meaning: The drive data set (DDS) is associated with a motor data set (MDS) that has no component assignment.

Possible causes

Source: SINAMICS G200 Basic converter P592; SINAMICS G210X converter P976

Series: G210, S120-S150

Drive: Component assignment missing

converter

Meaning:

Possible causes

Source: SINAMICS G210 converter P1132; SINAMICS S120_S150 P2778

Series: G220, S220

Drive: Component assignment missing

converter

Meaning: The drive data set (DDS) is linked to a motor data set (MDS) or encoder data set (EDS) with no component assigned.

Possible causes

Source: SINAMICS G220 Converter P1350; SINAMICS S220 Converter P2319

Series: S110

Drive: Component number missing

servo drive

Meaning: A motor data set (MDS) or encoder data set (EDS) without a component number is assigned to the drive data set (DDS).

Possible causes