Siemens F07491 fault code meaning

Siemens / F07491

Series: G120-CU250S-2

EPOS: Negative stop cam reached

converter

Meaning: A 0 signal was detected at BI: p2569, indicating that the negative stop cam has been reached. The negative stop cam was reached while running in the forward direction, indicating an incorrect stop cam connection. See: p2569 (EPOS reverse STOP cam)

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P981

Series: G120D

EPOS: Negative stop cam reached

converter

Meaning: A 0 signal was detected at BI: p2569, indicating that the negative stop cam has been reached. The negative stop cam was reached while moving in the positive direction, indicating an incorrect stop cam connection. See also: p2569 (EPOS Negative STOP cam)

Possible causes

Source: SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P881

Series: G130-G150

EPOS: Negative stop cam reached

converter

Meaning: A 0 signal was detected at binector input p2569, indicating that the negative stop cam has been reached. The negative stop cam was reached while moving in the positive direction, indicating incorrect stop cam connections.

Possible causes

Source: SINAMICS G130_G150 P1629

Series: G210, G220, S220

EPOS: Negative hardware limit switch reached

converter

Meaning: A 0 signal was detected at c2569, indicating that the negative hardware limit switch has been reached. The negative hardware limit switch has been reached while the direction of travel is positive, indicating an incorrect hardware limit switch connection. See also: c2569 (EPOS negative hardware limit switch)

Possible causes

Source: SINAMICS G210 converter P1128; SINAMICS G220 converter P1345; SINAMICS S220 converter P2313

Series: S110

EPOS: Negative stop cam reached

servo drive

Meaning: A 0 signal was detected at BI: p2569, indicating that the negative stop cam has been reached. The negative stop cam was reached while running in the forward direction, indicating an incorrect stop cam connection. See: p2569 (EPOS reverse STOP cam)

Possible causes

Source: SINAMICS S110 P1028

Series: S120-S150

EPOS: Negative stop cam reached

converter

Meaning: A 0 signal was detected at binary interconnection input p2569, indicating that the negative stop cam has been reached. The negative stop cam was reached while moving in the positive direction, indicating an incorrect stop cam connection. See also: p2569 (EPOS Negative STOP cam).

Possible causes

Source: SINAMICS S120_S150 P2773

Series: S200, S210

EPOS: Negative hardware limit switch reached

servo drive

Meaning: A 0 signal was detected at c2569, indicating that the negative hardware limit switch has been reached. The negative hardware limit switch has been reached while the direction of travel is positive, indicating an incorrect hardware limit switch connection. See also: c2569 (EPOS negative hardware limit switch)

Possible causes

Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P533; SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1333