Siemens F07491 fault code meaning
Siemens / F07491
Series: G120-CU250S-2
EPOS: Negative stop cam reached
converter
Meaning: A 0 signal was detected at BI: p2569, indicating that the negative stop cam has been reached. The negative stop cam was reached while running in the forward direction, indicating an incorrect stop cam connection. See: p2569 (EPOS reverse STOP cam)
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P981
Series: G120D
EPOS: Negative stop cam reached
converter
Meaning: A 0 signal was detected at BI: p2569, indicating that the negative stop cam has been reached. The negative stop cam was reached while moving in the positive direction, indicating an incorrect stop cam connection. See also: p2569 (EPOS Negative STOP cam)
Possible causes
Source: SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P881
Series: G130-G150
EPOS: Negative stop cam reached
converter
Meaning: A 0 signal was detected at binector input p2569, indicating that the negative stop cam has been reached. The negative stop cam was reached while moving in the positive direction, indicating incorrect stop cam connections.
Possible causes
Source: SINAMICS G130_G150 P1629
Series: G210, G220, S220
EPOS: Negative hardware limit switch reached
converter
Meaning: A 0 signal was detected at c2569, indicating that the negative hardware limit switch has been reached. The negative hardware limit switch has been reached while the direction of travel is positive, indicating an incorrect hardware limit switch connection. See also: c2569 (EPOS negative hardware limit switch)
Possible causes
Source: SINAMICS G210 converter P1128; SINAMICS G220 converter P1345; SINAMICS S220 converter P2313
Series: S110
EPOS: Negative stop cam reached
servo drive
Meaning: A 0 signal was detected at BI: p2569, indicating that the negative stop cam has been reached. The negative stop cam was reached while running in the forward direction, indicating an incorrect stop cam connection. See: p2569 (EPOS reverse STOP cam)
Possible causes
Source: SINAMICS S110 P1028
Series: S120-S150
EPOS: Negative stop cam reached
converter
Meaning: A 0 signal was detected at binary interconnection input p2569, indicating that the negative stop cam has been reached. The negative stop cam was reached while moving in the positive direction, indicating an incorrect stop cam connection. See also: p2569 (EPOS Negative STOP cam).
Possible causes
Source: SINAMICS S120_S150 P2773
Series: S200, S210
EPOS: Negative hardware limit switch reached
servo drive
Meaning: A 0 signal was detected at c2569, indicating that the negative hardware limit switch has been reached. The negative hardware limit switch has been reached while the direction of travel is positive, indicating an incorrect hardware limit switch connection. See also: c2569 (EPOS negative hardware limit switch)
Possible causes
Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P533; SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1333