Siemens F07452 fault code meaning
Siemens / F07452
Series: G120-CU250S-2
Position loop: Following error too large
converter
Meaning: The difference between the position reference and the actual position (dynamic following error mode, r2563) is greater than the tolerance (p2546). - The torque or acceleration capability of the drive has been exceeded. - The position measuring system has an error. - The position control direction is incorrect. - The mechanical system is jammed. - The run speed is too high or the change in the position reference is too large.
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P975
Series: G120D, S120-S150
Position loop: Following error too large
converter
Meaning: The difference between the position setpoint and the actual position (dynamic following error mode, r2563) exceeds the tolerance (p2546). - The torque or acceleration capability of the drive has been exceeded. - There is an error in the position measuring system. - The encoder cable is interrupted. - The position control direction is incorrect. - The mechanism is jammed. - The run speed is too high or the difference between position setpoints is too large.
Possible causes
Source: SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P874; SINAMICS S120_S150 P2764
Series: G130-G150
LR: Following error too high
converter
Meaning:
Possible causes
Source: G150 P865
Series: G210, S220
Position loop: Following error too large
converter
Meaning: The difference between the position setpoint and the actual position (dynamic following error mode, r2563) exceeds the tolerance (p2546). - The torque or acceleration capability of the drive is exceeded. - Error in the position measuring system. - Encoder cable interruption. - Incorrect position control direction. - Mechanical system jammed. - Run speed too high or position setpoint difference too large.
Possible causes
Source: SINAMICS G210 converter P1118; SINAMICS S220 converter P2302
Series: G220
Position loop: Following error too large
converter
Meaning:
Possible causes
Source: SINAMICS G220 Converter P1335
Series: S110
Position loop: Following error too large
servo drive
Meaning: The difference between the position reference and the actual position (dynamic following error mode, r2563) is greater than the tolerance (p2546). - The torque or acceleration capability of the drive has been exceeded. - The position measuring system has an error. - The position control direction is incorrect. - The mechanical system is jammed. - The run speed is too high or the change in the position reference is too large.
Possible causes
Source: SINAMICS S110 P1020
Series: S200
Position loop: Following error too large
servo drive
Meaning: The difference between the position setpoint and the actual position (dynamic following error mode, r2563) exceeds the tolerance (p2546). - The torque or acceleration capability of the drive is exceeded. - Error in the position measuring system. - Encoder cable interruption. - Incorrect position control direction. - Mechanical system jammed. - Run speed too high or position setpoint difference too large.
Possible causes
Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P523
Series: S210
Position loop: Following error too large
servo drive
Meaning: The difference between the position setpoint and the actual position (dynamic following error mode, r2563) exceeds the tolerance (p2546). - The torque or acceleration capability of the drive is exceeded. - Error in the position measuring system. - Encoder cable interruption. - Incorrect position control direction. - Mechanical system jammed. - Run speed too high or position setpoint difference too large.
Possible causes
Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1323