Siemens F07450 fault code meaning
Siemens / F07450
Series: G120-CU250S-2
Position loop: Static monitoring has triggered
converter
Meaning: The drive is outside the standstill window (p2542) after the standstill monitoring time (p2543) has elapsed. - Incorrect setting for inversion of the actual position value (p0410). - Standstill window (p2542) set too small. - Standstill monitoring time (p2543) set too short. - Position loop gain (p2538) too small. - Position loop gain too large (instability/vibration, p2538). - Mechanical overload. - Fault in the motor/converter connection cable (phase loss, incorrect phase connection). - Tracking mode selected when motor identification is selected (BI: p2655[0] = 1 signal). - Tracking mode selected when the function generator is selected (BI: p2655[0] = 1 signal) and position control deactivated (BI: p2550 = 0 signal).
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1382
Series: G120D
Static monitoring has been triggered
converter
Meaning: • The motor/drive cable connection is incorrect (phase loss or incorrect phase connection). • Tracking mode was selected when motor data identification was selected (BI: p2655[0] = 1 signal).
Possible causes
Source: Converter SINAMICS G120D, equipped with control unit CU250D-2 P324
Series: G130-G150
LR: Standstill monitoring has responded
converter
Meaning:
Possible causes
Source: G150 P865
Series: G220
Position loop: Standstill monitoring triggered
converter
Meaning: The drive is outside the standstill window (p2542) after the standstill monitoring time (p2543) has elapsed. - The actual position value inversion setting is incorrect (p0410). - The standstill window (p2542) is set too small. - The standstill monitoring time (p2543) is set too short. - The position loop gain (p2538) is too small. - The position loop gain is too large (instability/vibration, p2538). - The mechanical system is overloaded. - The motor/converter connection cable is faulty (phase loss, incorrect phase connection). - Tracking operation is selected when motor detection is selected (c2655[0] = 1 signal). - Tracking operation is selected when the function generator is selected (c2655[0] = 1 signal), and position control is disabled (c2550 = 0 signal).
Possible causes
Source: SINAMICS G220 Converter P1335
Series: S200
Position loop: Standstill monitoring triggered
servo drive
Meaning: The drive moved outside the standstill window (p2542) after the standstill monitoring time (p2543) expired. - The standstill window (p2542) is set too small. - The standstill monitoring time (p2543) is set too short. - The position loop gain (p2538) is too small. - The position loop gain is too large (instability/vibration, p2538). - The mechanical system is overloaded. - The connection cable between the motor and converter is faulty (phase loss or incorrectly connected phases).
Possible causes
Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P523
Series: S210
Position loop: Static monitoring has triggered
servo drive
Meaning:
Possible causes
Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1322