Siemens F07448 fault code meaning

Siemens / F07448

Series: G120-CU250S-2

Load gearbox: Linear axis position tracking exceeded the maximum range

converter

Meaning: On the configured linear axis/non-modulo axis, the currently valid motor encoder (encoder 1) has exceeded the maximum permissible travel range. The maximum travel range on the configured linear axis is 64 times p0421 (+/- 32 times). This range can be read in p2721 and is interpreted as the number of load revolutions.

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1381

Series: G130-G150

Load gearbox: Linear axis position tracking exceeded the maximum range

converter

Meaning:

Possible causes

Source: SINAMICS G130_G150 P1617

Series: G210

Load gearbox: Linear axis position tracking exceeded the maximum range

converter

Meaning: On the configured linear axis/non-modulo axis, the currently active motor encoder has exceeded the maximum permissible travel range. The maximum travel range on the configured linear axis is 64 times p0421 (+/- 32 times). This range can be read in p2721 and is interpreted as the number of load revolutions. Note: Only the motor encoder in the currently active drive data set is monitored. The currently active drive data set is displayed in x = r0051, and the corresponding motor encoder is set in p0187[x].

Possible causes

Source: SINAMICS G210 Converter P1116

Series: S110

Load gearbox: Position tracking for the linear axis exceeded the maximum range

servo drive

Meaning: On the configured linear axis/non-modulo axis, the currently active motor encoder (encoder 1) has exceeded the maximum permissible travel range. The maximum travel range on the configured linear axis is 64 times p0421 (+/- 32 times). This range is read in p2721 and interpreted as the number of load revolutions.

Possible causes

Source: SINAMICS S110 P1018

Series: S120-S150

Load gearbox: Linear axis position tracking exceeded the maximum range

converter

Meaning: On the configured linear axis/non-modulo axis, the currently active motor encoder (encoder 1) has exceeded the maximum permissible travel range. The maximum travel range on the configured linear axis is 64 times p0421 (+/- 32 times). This range is read in p2721 and interpreted as the number of load revolutions.

Possible causes

Source: SINAMICS S120_S150 P2762

Series: S200

Load gearbox: Linear axis position tracking exceeded the maximum range

servo drive

Meaning: On the configured linear/non-modulo axis, the currently active motor encoder has exceeded the maximum permissible traversing range. The maximum traversing range on the configured linear axis is 64 times p0421 (+/- 32 times). This range can be read in p2721 and is interpreted as the number of load revolutions.

Possible causes

Source: SINAMICS S200 Pulse train input_SIMOTICS S-1FL2 P504