Siemens F07447 fault code meaning

Siemens / F07447

Series: DCM-6RA80

Load gearbox: Position tracking exceeded the maximum actual value

DC drive

Meaning:

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1009

Series: G120-CU250S-2, G130-G150, S120-S150

Load gearbox: Position tracking exceeded the maximum actual value

converter

Meaning: With position tracking configured for the load gearbox, the drive/encoder (motor encoder) detected a maximum actual absolute position value (r2723) that cannot be represented in 32 bits. Maximum value: p0408 * p2721 * 2^p0419

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1381; SINAMICS G130_G150 P1617; SINAMICS S120_S150 P2762

Series: G210

Load gearbox: Position tracking exceeded the maximum actual value

converter

Meaning: During configured position tracking of the load gearbox, the drive/encoder (motor encoder) detected a maximum actual absolute position value (r2723) that cannot be represented in 32 bits. Maximum value: p0408 * p2721 * 2^p0419

Possible causes

Source: SINAMICS G210 Converter P1116

Series: G220, S220

Load gearbox: Position tracking exceeded the maximum actual value

converter

Meaning:

Possible causes

Source: SINAMICS G220 Converter P1333; SINAMICS S220 Converter P2299

Series: S110

Load gearbox: Position tracking exceeded the maximum actual value

servo drive

Meaning: With position tracking configured for the load gearbox, the drive/encoder (motor encoder) detected a maximum actual absolute position value (r2723) that cannot be represented in 32 bits. Maximum value: p0408 * p2721 * 2^p0419

Possible causes

Source: SINAMICS S110 P1018

Series: S200

Load gearbox: Position tracking exceeded the maximum actual value

servo drive

Meaning: During configured position tracking of the load gearbox, the drive/encoder (motor encoder) detected a maximum actual absolute position value (r2723) that cannot be represented in 32 bits. Maximum value: p0408 * p2721 * 2^p0419

Possible causes

Source: SINAMICS S200 Pulse train input_SIMOTICS S-1FL2 P504