Siemens F07443 fault code meaning

Siemens / F07443

Series: G120-CU250S-2, G120D

Position loop: Reference point coordinate exceeded the permissible range

converter

Meaning: During encoder adjustment, the reference point coordinate received via CI p2599 exceeds half the encoder range and cannot be set as the current axis position.

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1381; SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P873

Series: G130-G150

Position loop: Reference point coordinate exceeded the permissible range

converter

Meaning:

Possible causes

Source: SINAMICS G130_G150 P1616

Series: S110

Position loop: Reference point coordinate exceeded the permissible range

servo drive

Meaning: During encoder adjustment, the reference point coordinate received via CI p2599 exceeds half the encoder range and cannot be set as the current axis position.

Possible causes

Source: SINAMICS S110 P1018

Series: S200, S210

Position control loop: Reference point coordinates exceeded the permissible range

servo drive

Meaning: The reference point coordinate (p2599) received during encoder calibration exceeds half the encoder range and cannot be set as the current axis position.

Possible causes

Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P521; SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1322