Siemens F07442 fault code meaning

Siemens / F07442

Series: G120-CU250S-2

Position loop: Multi-turn resolution and modulo range mismatch

converter

Meaning: The ratio of the multi-turn resolution to the modulo range (p2576) is not an integer. This causes the adjustment to be reset because the actual position value cannot be reproduced after power-on.

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1380

Series: G120D, G130-G150

Position loop: Multi-turn resolution and modulo range mismatch

converter

Meaning: The ratio of the multi-turn resolution to the modulo range (p2576) is not an integer. This will reset the adjustment because the actual position value cannot be reconstructed after power-on.

Possible causes

Source: SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P873; SINAMICS G130_G150 P1616

Series: S110, S210

Position loop: Multi-turn resolution and modulo range mismatch

servo drive

Meaning: The ratio of the multi-turn resolution to the modulo range (p2576) is not an integer. This will reset the adjustment because the actual position value cannot be reconstructed after power-on.

Possible causes

Source: SINAMICS S110 P1017; SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1322

Series: S120-S150

Position loop: Multi-turn resolution and modulo range mismatch

converter

Meaning:

Possible causes

Source: SINAMICS S120_S150 P2760

Series: S200

Position loop: Multi-turn resolution and modulo range mismatch

servo drive

Meaning: The ratio of the multi-turn resolution to the modulo range (p2576) is not an integer. Calibration will be reset because the actual position value cannot be reproduced after power-on. System messages 12.3 Faults and alarms SINAMICS S200 PROFINET Servo Drive System with SIMOTICS S-1FL2 518 Operating Instructions, 06/2026, FW V6.7, A5E51646752F AG

Possible causes

Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P520

Series: S220

Position loop: Multi-turn resolution and modulo range mismatch

converter

Meaning: The ratio of the multi-turn resolution to the modulo range (p2576) is not an integer. This causes calibration to be reset because the actual position value cannot be generated again after power-on. Faults and alarms 5.5 List of faults and alarms SINAMICS S220 Converter Parameter Manual, 08/2026, FW V6.7, A5E53307549F AB 2295

Possible causes

Source: SINAMICS S220 converter P2297