Siemens F07439 fault code meaning

Siemens / F07439

Series: G120-CU240B-E-2

Drive: Higher current loop dynamic response not permitted

converter

Meaning: Although the "Increase current loop dynamic response" function is selected (p1810.11 = 1), the power unit (r0192.27 = 0) or encoderless safety motion monitoring (9506 = 1) does not support this function.

Possible causes

Source: SINAMICS G120 Control Unit CU240B_E-2 P670

Series: S110

Drive: Higher current loop dynamic response not permitted

servo drive

Meaning: Although the "Increase current loop dynamic response" function (p1810.11 = 1) is selected, the power unit (r0192.27 = 0) or encoderless safe motion monitoring (9506 = 1) does not support this function.

Possible causes

Source: SINAMICS S110 P1016