Siemens F07434 fault code meaning

Siemens / F07434

Series: G120-CU250S-2, G130-G150

Drive: Cannot change the direction of rotation while pulses are enabled

converter

Meaning: A switch was made while pulses were enabled to a drive data set with a different direction of rotation setting (p1821). In general, the motor direction of rotation can only be changed using p1821 while pulses are inhibited.

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1379; SINAMICS G130_G150 P1615

Series: G200, G210X, G220

Drive: Cannot change the direction of rotation while pulses are enabled

converter

Meaning: The drive data set was switched while pulses were enabled, and the new data set specifies a different direction of rotation (p1821). In general, the motor direction of rotation can only be changed via p1821 when pulses are inhibited.

Possible causes

Source: SINAMICS G200 converter P714; SINAMICS G210X converter P973; SINAMICS G220 converter P1329

Series: G210

Drive: Cannot change the direction of rotation while pulses are enabled

converter

Meaning:

Possible causes

Source: SINAMICS G210 converter P1112

Series: S110

Drive: Cannot change the direction of rotation while pulses are enabled

servo drive

Meaning: A switch was made while pulses were enabled to a drive data set with a different direction of rotation setting (p1821). In general, the motor direction of rotation can only be changed using p1821 while pulses are inhibited.

Possible causes

Source: SINAMICS S110 P1016

Series: S200

Drive: Cannot change the direction of rotation while pulses are enabled

servo drive

Meaning: A drive data set configured for a different direction of rotation (p1821) was selected while pulses were enabled. In general, the motor direction of rotation can only be changed via p1821 when pulses are inhibited. System messages 12.3 Faults and alarms SINAMICS S200 PROFINET Servo Drive System with SIMOTICS S-1FL2 Operating Instructions, 06/2026, FW V6.7, A5E51646752F AG 517

Possible causes

Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P519

Series: S210

Drive: Cannot change the direction of rotation while pulses are enabled

servo drive

Meaning: The drive data set was switched while pulses were enabled. The new data set specifies a different direction of rotation (p1821). In general, the motor direction of rotation can only be changed via p1821 when pulses are inhibited.

Possible causes

Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1321