Siemens F07434 fault code meaning
Siemens / F07434
Series: G120-CU250S-2, G130-G150
Drive: Cannot change the direction of rotation while pulses are enabled
converter
Meaning: A switch was made while pulses were enabled to a drive data set with a different direction of rotation setting (p1821). In general, the motor direction of rotation can only be changed using p1821 while pulses are inhibited.
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1379; SINAMICS G130_G150 P1615
Series: G200, G210X, G220
Drive: Cannot change the direction of rotation while pulses are enabled
converter
Meaning: The drive data set was switched while pulses were enabled, and the new data set specifies a different direction of rotation (p1821). In general, the motor direction of rotation can only be changed via p1821 when pulses are inhibited.
Possible causes
Source: SINAMICS G200 converter P714; SINAMICS G210X converter P973; SINAMICS G220 converter P1329
Series: G210
Drive: Cannot change the direction of rotation while pulses are enabled
converter
Meaning:
Possible causes
Source: SINAMICS G210 converter P1112
Series: S110
Drive: Cannot change the direction of rotation while pulses are enabled
servo drive
Meaning: A switch was made while pulses were enabled to a drive data set with a different direction of rotation setting (p1821). In general, the motor direction of rotation can only be changed using p1821 while pulses are inhibited.
Possible causes
Source: SINAMICS S110 P1016
Series: S200
Drive: Cannot change the direction of rotation while pulses are enabled
servo drive
Meaning: A drive data set configured for a different direction of rotation (p1821) was selected while pulses were enabled. In general, the motor direction of rotation can only be changed via p1821 when pulses are inhibited. System messages 12.3 Faults and alarms SINAMICS S200 PROFINET Servo Drive System with SIMOTICS S-1FL2 Operating Instructions, 06/2026, FW V6.7, A5E51646752F AG 517
Possible causes
Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P519
Series: S210
Drive: Cannot change the direction of rotation while pulses are enabled
servo drive
Meaning: The drive data set was switched while pulses were enabled. The new data set specifies a different direction of rotation (p1821). In general, the motor direction of rotation can only be changed via p1821 when pulses are inhibited.
Possible causes
Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1321