Siemens F07312 fault code meaning
Siemens / F07312
Series: G120X
Power supply bypass switch
converter
Meaning: Fault value (r0949, bit-coded): Bit 1: Switch feedback "closed" is missing. Bit 2: Switch feedback "open" is missing. Bit 3: Switch feedback is too slow. After switching on, forward feedback is awaited. If feedback is received only after the specified time has elapsed, a fault trip occurs. Bit 6: Power supply switch feedback does not match the bypass status. The power supply switch is closed without a bypass request when switching on or switching on the motor. See also: p1260, r1261, p1266, p1267, p1269, p1274 Alarms, faults and system messages 10.6 List of fault codes and alarm codes SINAMICS G120X Converter 1374 Operating Instructions, 06/2021, FW V1.04, A5E44751209F AF
Possible causes
Source: SINAMICS G120X converter P1376
Series: G120XA
Power supply bypass switch
converter
Meaning: Fault value (r0949, bit-coded): Bit 1: Switch feedback indicating "closed" is missing. Bit 2: Switch feedback indicating "open" is missing. Bit 3: Switch feedback is too slow. After switch-on, the system waits for affirmative feedback. If feedback is received only after the specified time has elapsed, a fault trip occurs. Bit 6: Power switch feedback and bypass status mismatch. During switch-on or motor switch-on, the power switch is closed without a bypass request. See also: p1260, r1261, p1266, p1267, p1269, p1274
Possible causes
Source: SINAMICS G120XA PN converter P1287
Series: G130-G150
Power supply bypass switch
converter
Meaning: %1 bin Message class: Application/technology function fault (17) Drive object: VECTOR_G Component: None Broadcast: GLOBAL Response: OFF2 Acknowledgment: Immediate Cause: The feedback from the power switch is implausible.
Possible causes
Source: SINAMICS G130_G150 P1605
Series: G200, G220
Bypass power supply switch
converter
Meaning: %1 bin Component: None. Response: OFF2. Acknowledgment: Immediate. Cause: Implausible feedback from the power switch.
Possible causes
Source: SINAMICS G200 converter P707; SINAMICS G220 converter P1320
Series: G210X
Bypass power supply switch
converter
Meaning: %1 bin Component: None. Broadcast: Global. Response: OFF2. Acknowledgment: Immediate. Cause: The power switch feedback is implausible.
Possible causes
Source: SINAMICS G210X converter P965
Series: S220
Bypass power supply switch
converter
Meaning: %1 bin Model: Vector Component: None Broadcast: Global Reaction: OFF2 Acknowledgment: Immediate Cause: The feedback from the power switch is implausible.
Possible causes
Source: SINAMICS S220 converter P2270