Siemens F07300 fault code meaning
Siemens / F07300
Series: G110M, G115D, G120-CU240B-E-2, G120-CU250S-2, G120C, G120D, S120-S150
Drive: Missing power supply contactor feedback
converter
Meaning: The power supply contactor failed to close within the time specified by p0861. - The power supply contactor failed to open within the time specified by p0861. - The power supply contactor failed during operation. - The power supply contactor remains closed even though the rectifier is disabled.
Possible causes
Source: SINAMICS G110M P705; SINAMICS G115D P763; SINAMICS G120, Control Unit CU240B-2_CU240E-2 P735; SINAMICS G120, Control Unit CU250S-2 P1368; SINAMICS G120C P679; SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P869; SINAMICS S120_S150 P2736
Series: G120X, G120XA
Drive: Missing power supply contactor feedback
converter
Meaning: The power supply contactor failed to close within the time specified in p0861. - The power supply contactor failed to open within the time specified in p0861. - The power supply contactor developed a fault during operation. - The power supply contactor remains closed even though the rectifier is disabled.
Possible causes
Source: SINAMICS G120X converter P1376; SINAMICS G120XA PN converter P1286
Series: G130-G150
r3402
converter
Meaning:
Possible causes
Source: SINAMICS G130_G150 P1370
Series: G200, G210
Drive: Power supply contactor feedback signal missing
converter
Meaning:
Possible causes
Source: SINAMICS G200 Basic Converter P582; SINAMICS G210 Converter P1101
Series: G220
c13845[C]
converter
Meaning:
Possible causes
Source: SINAMICS G220 Converter P1140
Series: S110
Drive: Missing power supply contactor feedback
servo drive
Meaning: The power supply contactor failed to close within the time specified by p0861. - The power supply contactor failed to open within the time specified by p0861. - The power supply contactor failed during operation. - The power supply contactor remains closed even though the rectifier is disabled.
Possible causes
Source: SINAMICS S110 P1009
Series: S220
Infeed internal
converter
Meaning:
Possible causes
Source: SINAMICS S220 Converter P1965