Siemens F07300 fault code meaning

Siemens / F07300

Series: G110M, G115D, G120-CU240B-E-2, G120-CU250S-2, G120C, G120D, S120-S150

Drive: Missing power supply contactor feedback

converter

Meaning: The power supply contactor failed to close within the time specified by p0861. - The power supply contactor failed to open within the time specified by p0861. - The power supply contactor failed during operation. - The power supply contactor remains closed even though the rectifier is disabled.

Possible causes

Source: SINAMICS G110M P705; SINAMICS G115D P763; SINAMICS G120, Control Unit CU240B-2_CU240E-2 P735; SINAMICS G120, Control Unit CU250S-2 P1368; SINAMICS G120C P679; SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P869; SINAMICS S120_S150 P2736

Series: G120X, G120XA

Drive: Missing power supply contactor feedback

converter

Meaning: The power supply contactor failed to close within the time specified in p0861. - The power supply contactor failed to open within the time specified in p0861. - The power supply contactor developed a fault during operation. - The power supply contactor remains closed even though the rectifier is disabled.

Possible causes

Source: SINAMICS G120X converter P1376; SINAMICS G120XA PN converter P1286

Series: G130-G150

r3402

converter

Meaning:

Possible causes

Source: SINAMICS G130_G150 P1370

Series: G200, G210

Drive: Power supply contactor feedback signal missing

converter

Meaning:

Possible causes

Source: SINAMICS G200 Basic Converter P582; SINAMICS G210 Converter P1101

Series: G220

c13845[C]

converter

Meaning:

Possible causes

Source: SINAMICS G220 Converter P1140

Series: S110

Drive: Missing power supply contactor feedback

servo drive

Meaning: The power supply contactor failed to close within the time specified by p0861. - The power supply contactor failed to open within the time specified by p0861. - The power supply contactor failed during operation. - The power supply contactor remains closed even though the rectifier is disabled.

Possible causes

Source: SINAMICS S110 P1009

Series: S220

Infeed internal

converter

Meaning:

Possible causes

Source: SINAMICS S220 Converter P1965