Siemens F07220 fault code meaning
Siemens / F07220
Series: DCM-6RA80
Drive: Missing "Control via PLC"
DC drive
Meaning: The "Control via PLC" signal is missing during operation. - The BI p0854 connection for "Control via PLC" is incorrect. - The higher-level control system canceled the "Control via PLC" signal. - Data transmission via the fieldbus (master/drive) has been interrupted.
Possible causes
Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1008
Series: G110M, G120-CU240B-E-2, G120-CU250S-2, S120-S150
Drive: "Control via PLC" missing
converter
Meaning: The "Control via PLC" signal is missing during operation. - Incorrect BI p0854 connection for "Control via PLC". - The higher-level control system has removed the "Control via PLC" signal. - Data transmission via the fieldbus (master/drive) has been interrupted.
Possible causes
Source: SINAMICS G110M P705; SINAMICS G120, Control unit CU240B-2_CU240E-2 P735; SINAMICS G120, Control unit CU250S-2 P1368; SINAMICS S120_S150 P2736
Series: G115D, G120C, G120D
Drive: "Control via PLC" missing
converter
Meaning: The "Control via PLC" signal is missing during operation. - The BI p0854 connection for "Control via PLC" is incorrect. - The higher-level control system removed the "Control via PLC" signal. - Data transmission via the fieldbus (higher-level control system/drive) was interrupted.
Possible causes
Source: SINAMICS G115D P763;SINAMICS G120C P679;SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P869
Series: G120X, G120XA
Drive: "Control via PLC" missing
converter
Meaning: The "Control via PLC" signal is missing during operation. - Incorrect BI p0854 connection for "Control via PLC". - The higher-level control system has withdrawn the "Control via PLC" signal. - Data transmission via the fieldbus (master/drive) has been interrupted.
Possible causes
Source: SINAMICS G120X converter P1376; SINAMICS G120XA PN converter P1286
Series: G130-G150
Drive: "Control via PLC" missing
converter
Meaning:
Possible causes
Source: SINAMICS G130_G150 P1603
Series: G200, G210
Drive: "Control via PLC" missing
converter
Meaning: The "Control via PLC" signal is missing during run. - Incorrect connection of the binector input for "Control via PLC" (c0854). - The higher-level controller removed the "Control via PLC" signal. - Fieldbus data transmission (master/drive) was interrupted.
Possible causes
Source: SINAMICS G200 Basic Converter P582; SINAMICS G210 Converter P1101
Series: G210X, G220, S220
Drive: "Control via PLC" missing
converter
Meaning:
Possible causes
Source: SINAMICS G210X Converter P963; SINAMICS G220 Converter P1318; SINAMICS S220 Converter P2268
Series: S110
Drive: "Control via PLC" missing
servo drive
Meaning: The "Control via PLC" signal is missing during operation. - Incorrect BI p0854 connection for "Control via PLC". - The higher-level control system has removed the "Control via PLC" signal. - Data transmission via the fieldbus (master/drive) has been interrupted.
Possible causes
Source: SINAMICS S110 P1009
Series: S200
Drive: "Control via PLC" missing
servo drive
Meaning: The "Control via PLC" signal is missing during run. - The higher-level controller removed the "Control via PLC" signal. - Fieldbus data transmission (master/drive) was interrupted.
Possible causes
Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P516
Series: S210
Drive: "Control via PLC" missing
servo drive
Meaning: The signal "Control via PLC" is missing during run. - The higher-level controller has withdrawn the signal "Control via PLC". - Fieldbus data transmission (master/drive) has been interrupted. Faults and alarms 18.2 List of faults and alarms SINAMICS S210 servo drive system equipped with SIMOTICS S-1FK2 and S-1FT2 1316 Operating Instructions, 05/2025, FW V6.4, A5E52380168F AF
Possible causes
Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1318