Siemens F07220 fault code meaning

Siemens / F07220

Series: DCM-6RA80

Drive: Missing "Control via PLC"

DC drive

Meaning: The "Control via PLC" signal is missing during operation. - The BI p0854 connection for "Control via PLC" is incorrect. - The higher-level control system canceled the "Control via PLC" signal. - Data transmission via the fieldbus (master/drive) has been interrupted.

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1008

Series: G110M, G120-CU240B-E-2, G120-CU250S-2, S120-S150

Drive: "Control via PLC" missing

converter

Meaning: The "Control via PLC" signal is missing during operation. - Incorrect BI p0854 connection for "Control via PLC". - The higher-level control system has removed the "Control via PLC" signal. - Data transmission via the fieldbus (master/drive) has been interrupted.

Possible causes

Source: SINAMICS G110M P705; SINAMICS G120, Control unit CU240B-2_CU240E-2 P735; SINAMICS G120, Control unit CU250S-2 P1368; SINAMICS S120_S150 P2736

Series: G115D, G120C, G120D

Drive: "Control via PLC" missing

converter

Meaning: The "Control via PLC" signal is missing during operation. - The BI p0854 connection for "Control via PLC" is incorrect. - The higher-level control system removed the "Control via PLC" signal. - Data transmission via the fieldbus (higher-level control system/drive) was interrupted.

Possible causes

Source: SINAMICS G115D P763;SINAMICS G120C P679;SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P869

Series: G120X, G120XA

Drive: "Control via PLC" missing

converter

Meaning: The "Control via PLC" signal is missing during operation. - Incorrect BI p0854 connection for "Control via PLC". - The higher-level control system has withdrawn the "Control via PLC" signal. - Data transmission via the fieldbus (master/drive) has been interrupted.

Possible causes

Source: SINAMICS G120X converter P1376; SINAMICS G120XA PN converter P1286

Series: G130-G150

Drive: "Control via PLC" missing

converter

Meaning:

Possible causes

Source: SINAMICS G130_G150 P1603

Series: G200, G210

Drive: "Control via PLC" missing

converter

Meaning: The "Control via PLC" signal is missing during run. - Incorrect connection of the binector input for "Control via PLC" (c0854). - The higher-level controller removed the "Control via PLC" signal. - Fieldbus data transmission (master/drive) was interrupted.

Possible causes

Source: SINAMICS G200 Basic Converter P582; SINAMICS G210 Converter P1101

Series: G210X, G220, S220

Drive: "Control via PLC" missing

converter

Meaning:

Possible causes

Source: SINAMICS G210X Converter P963; SINAMICS G220 Converter P1318; SINAMICS S220 Converter P2268

Series: S110

Drive: "Control via PLC" missing

servo drive

Meaning: The "Control via PLC" signal is missing during operation. - Incorrect BI p0854 connection for "Control via PLC". - The higher-level control system has removed the "Control via PLC" signal. - Data transmission via the fieldbus (master/drive) has been interrupted.

Possible causes

Source: SINAMICS S110 P1009

Series: S200

Drive: "Control via PLC" missing

servo drive

Meaning: The "Control via PLC" signal is missing during run. - The higher-level controller removed the "Control via PLC" signal. - Fieldbus data transmission (master/drive) was interrupted.

Possible causes

Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P516

Series: S210

Drive: "Control via PLC" missing

servo drive

Meaning: The signal "Control via PLC" is missing during run. - The higher-level controller has withdrawn the signal "Control via PLC". - Fieldbus data transmission (master/drive) has been interrupted. Faults and alarms 18.2 List of faults and alarms SINAMICS S210 servo drive system equipped with SIMOTICS S-1FK2 and S-1FT2 1316 Operating Instructions, 05/2025, FW V6.4, A5E52380168F AF

Possible causes

Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1318