Siemens F062 fault code meaning

Siemens / F062

Series: 6RA70

Parameter memory fault

DC drive

Meaning: (Valid in all operating states.) Software monitoring of the correct operation of the EEPROM module (nonvolatile memory) on the A7009 board. The value of EEPROM includes all data that must be protected in the event of a power supply failure (i.e. parameter values and process data that must remain stored during a power supply failure). The following are monitored:

Possible causes

Source: 6ra70_c P435