Siemens F058 fault code meaning

Siemens / F058

Series: 6RA70

Inconsistent parameter settings

DC drive

Meaning: (Valid in operating states ≤ o6.) Inconsistent values have been set in interrelated parameters. 2 Incorrect parameter settings for the speed-dependent current limit (the following applies: P105>P107 (I1>I2) and P104 < P106 (n1<n2)). 3 Magnetization curves do not match. 4 The first threshold for speed controller P gain adaptation, set in parameter P556, is higher than the second threshold, set in parameter P559. 5 P557 is set greater than P560. 6 P558 is set greater than P561. 7 If P083=1 (analog tachogenerator), P746 cannot equal 0 (main actual value not connected). 8 If P083=2 (pulse encoder), P140 cannot equal 0 (no pulse encoder installed). 9 If P083=3 (EMF control), P081 cannot equal 1 (field-weakening operation). 10 P090 (supply voltage stabilization time)>P086 (auto restart time). 11 P090 (supply voltage stabilization time)>P0.

Possible causes