Siemens F03000 fault code meaning

Siemens / F03000

Series: DCM-6RA80

NVRAM error during operation

DC drive

Meaning:

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1000

Series: G110M, G120-CU240B-E-2, G120-CU250S-2, G120C, G120X, G120XA, G130-G150

NVRAM error during operation

converter

Meaning: An error occurred while performing operation p7770 = 1 or 2 on the NVRAM data.

Possible causes

Source: SINAMICS G110M P697; SINAMICS G120, Control unit CU240B-2_CU240E-2 P728; SINAMICS G120, Control unit CU250S-2 P1352; SINAMICS G120C P671; SINAMICS G120X converter P1367; SINAMICS G120XA PN converter P1278; SINAMICS G130_G150 P1575

Series: G115D, G120D, S120-S150, S220

NVRAM error during operation

converter

Meaning:

Possible causes

Source: SINAMICS G115D P753; SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P861; SINAMICS S120_S150 P2685; SINAMICS S220 Converter P2209

Series: G200, G210, G210X

NVRAM error during operation

converter

Meaning: An error occurred while reading or writing NVRAM data.

Possible causes

Source: SINAMICS G200 converter P698; SINAMICS G210 converter P1091; SINAMICS G210X converter P953

Series: S110

NVRAM error during operation

servo drive

Meaning: An error occurred while performing operation p7770 = 1, 2 on NVRAM data.

Possible causes

Source: SINAMICS S110 P1000