Siemens F02153 fault code meaning
Siemens / F02153
Series: DCM-6RA80
TEC: Technology function does not exist
DC drive
Meaning: A technology function (e.g. a technology extension module or DCB library) is not available on the drive device. A technology function that is not available on the drive device was activated during configuration. This can occur during project download or upload.
Possible causes
Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1000
Series: G130-G150, S120-S150
TEC: Technology function does not exist
converter
Meaning: A technology function (e.g. a technology extension module or DCB library) is not available on the drive device. A technology function that is not available on the drive device was activated during configuration. This can occur during project download or upload.
Possible causes
Source: SINAMICS G130_G150 P1575; SINAMICS S120_S150 P2685
Series: G200, G210, G210X, S220
TEC: Technology function does not exist
converter
Meaning: The technology functions (e.g., Technology Extension, DCB library) are not available on the converter, or the current version is too old. A technology function that is unavailable on the converter or available only in an older version was activated during configuration. This can occur during project download or at start.
Possible causes
Source: SINAMICS G200 converter P698; SINAMICS G210 converter P1091; SINAMICS G210X converter P953; SINAMICS S220 converter P2209
Series: G220
TEC: Technology function does not exist
converter
Meaning:
Possible causes
Source: SINAMICS G220 Converter P1297
Series: S200
TEC: Technology function does not exist
servo drive
Meaning: The technology function is not available on the converter, or the current version is too old. A technology function unavailable on the converter, or available only in an older version, was activated during configuration. This can occur during project download or at start. System messages 11.3 Faults and alarms SINAMICS S200 Spindle Drive 366 Operating Instructions, 06/2026, FW V6.7, A5E54447397B AA
Possible causes
Source: SINAMICS S200 Spindle Drive P368