Siemens F01946 fault code meaning

Siemens / F01946

Series: DCM-6RA80

PROFIBUS: Connection interruption with publisher

DC drive

Meaning: %1 bin Message class: Communication fault with the higher-level controller (9) Drive object: All objects Component: None Propagation: LOCAL Reaction: OFF1 (OFF2, OFF3, None) Acknowledgment: Immediately (power-on) Cause: During cyclic operation of PROFIBUS slave-to-slave communication, the connection between the drive object and at least one publisher was interrupted.

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P985

Series: G110M, G115D, G120-CU240B-E-2, G120C

PROFIBUS: Connection interruption with publisher

converter

Meaning: During cyclic operation of PROFIBUS slave-to-slave communication, the connection to at least one publisher was interrupted.

Possible causes

Source: SINAMICS G110M P691; SINAMICS G115D P748; SINAMICS G120, Control unit CU240B-2_CU240E-2 P723; SINAMICS G120C P666

Series: G120-CU250S-2

PROFIBUS: Connection interruption with publisher

converter

Meaning: %1 bin Drive object: CU250S_V, CU250S_V_CAN, CU250S_V_DP, CU250S_V_PN. Reaction: OFF1 (OFF2, OFF3, none). Acknowledgment: Immediate (power-on). Cause: During cyclic PROFIBUS slave-to-slave communication, the connection to at least one publisher was interrupted.

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1341

Series: G120D

PROFIBUS: Connection interruption with publisher

converter

Meaning:

Possible causes

Source: SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P856

Series: G120X, G120XA

PROFIBUS: Connection interruption with publisher

converter

Meaning: During cyclic PROFIBUS slave-to-slave communication, the connection to at least one publisher has been interrupted.

Possible causes

Source: SINAMICS G120X Converter P1362; SINAMICS G120XA PN Converter P1277

Series: G130-G150

PROFIBUS: Connection interruption with publisher

converter

Meaning: %1 bin Message class: Communication fault with the higher-level controller (9) Drive object: All objects Component: None Broadcast: LOCAL Reaction: Vector: OFF1 (OFF2, OFF3, None) Infeed: OFF1 (OFF2, None) Acknowledgment: Immediate (power-on) Cause: During cyclic operation of PROFIBUS slave-to-slave communication, the connection between the drive object and at least one publisher was interrupted.

Possible causes

Source: SINAMICS G130_G150 P1558

Series: S110

PROFIBUS: Connection interruption with publisher

servo drive

Meaning: %1 bin. Drive object: All objects. Reaction: OFF1 (OFF2, OFF3, None). Acknowledgment: Immediate (power-on). Cause: During cyclic operation of PROFIBUS slave-to-slave communication, the connection between the drive object and at least one publisher has been interrupted.

Possible causes

Source: SINAMICS S110 P991

Series: S120-S150

PROFIBUS: Connection interruption with publisher

converter

Meaning: %1 bin Message class: Communication fault with the higher-level controller (9) Drive object: All objects Component: None Broadcast: LOCAL Reaction: Infeed: OFF1 (OFF2, None) Servo: OFF1 (OFF2, OFF3, None) Vector: OFF1 (OFF2, OFF3, None) Hla: OFF1 (OFF2, OFF3, None) Acknowledgment: Immediate (power-on) Cause: During cyclic operation of PROFIBUS slave-to-slave communication, the connection between the drive object and at least one publisher was interrupted.

Possible causes

Source: SINAMICS S120_S150 P2667