Siemens F01910 fault code meaning
Siemens / F01910
Series: DCM-6RA80
Fieldbus setpoint timeout
DC drive
Meaning: Reception of setpoints from the fieldbus interface (onboard, PROFIBUS/PROFINET/USS) has been interrupted. - The bus connection is open. - The controller is switched off. - The controller is set to STOP. See also: p2040 (Fieldbus SS monitoring time), p2047 (PROFIBUS additional monitoring time)
Possible causes
Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P982
Series: G110M
Fieldbus setpoint timeout
converter
Meaning: Reception of setpoints from the fieldbus interface was interrupted. - The bus connection is open. - The communication partner is switched off. PROFIBUS: - The PROFIBUS master is set to STOP. AS-i (Actuator Sensor Interface): - Check the status in r2015. See: r2015 (AS-i status), p2040 (fieldbus SS monitoring time), p2047 (PROFIBUS additional monitoring time)
Possible causes
Source: SINAMICS G110M P690
Series: G115D
Fieldbus setpoint timeout
converter
Meaning: Reception of setpoints from the fieldbus interface was interrupted. - The bus connection is open. - The communication partner is switched off. AS-i (Actuator Sensor Interface): - Check the status in r2015. See also: r2015 (AS-i status), p2040 (Fieldbus SS monitoring time)
Possible causes
Source: SINAMICS G115D P747
Series: G120-CU230P-2
Setpoint timeout
converter
Meaning:
Possible causes
Source: Converter SINAMICS G120, equipped with control unit CU230P-2 P491
Series: G120-CU240B-E-2
Fieldbus SS setpoint timeout
converter
Meaning: Reception of reference values from the fieldbus interface was interrupted. - Bus connection open. - Communication partner switched off. PROFIBUS: - The PROFIBUS master is set to STOP. See: p2040 (Fieldbus SS monitoring time), p2047 (PROFIBUS Additional monitoring time)
Possible causes
Source: SINAMICS G120, Control Unit CU240B-2_CU240E-2 P722
Series: G120-CU250S-2
Fieldbus setpoint timeout
converter
Meaning: Reception of setpoints from the fieldbus interface (onboard, PROFIBUS/PROFINET/USS) has been interrupted. - The bus connection is open. - The controller is switched off. - The controller is set to STOP. See: p2040 (Fieldbus SS monitoring time), p2047 (PROFIBUS additional monitoring time).
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1338
Series: G120C
Fieldbus SS setpoint timeout
converter
Meaning: Reception of reference values from the fieldbus interface was interrupted. - Bus connection open. - Communication partner switched off. PROFIBUS: - PROFIBUS master is set to STOP. See also: p2040 (Fieldbus SS monitoring time), p2047 (PROFIBUS additional monitoring time)
Possible causes
Source: SINAMICS G120C P665
Series: G120D
Fieldbus SS setpoint timeout
converter
Meaning: Reception of setpoints via the fieldbus interface has been interrupted. - The bus connection is open. - The communication partner is switched off. PROFIBUS: - The PROFIBUS master is set to STOP. See also: p2047 (PROFIBUS Additional monitoring time)
Possible causes
Source: SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P856
Series: G120P-Cabinet, G210
Fieldbus setpoint timeout
converter
Meaning:
Possible causes
Source: SINAMICS G120P Cabinet P510; SINAMICS G210 converter P1074
Series: G120X
Fieldbus SS setpoint timeout
converter
Meaning: Reception of setpoints from the fieldbus interface has been interrupted. - The bus connection is open. - The communication partner is switched off. CU230P-2 DP: - The PROFIBUS master is set to STOP. See also: p2040, p2047 Alarms, faults, and system messages 10.6 List of fault codes and alarm codes SINAMICS G120X converter Operating Instructions, 06/2021, FW V1.04, A5E44751209F AF 1359
Possible causes
Source: SINAMICS G120X converter P1361
Series: G120XA
Fieldbus SS setpoint timeout
converter
Meaning: Reception of setpoints from the fieldbus interface has been interrupted. - The bus connection is open. - The communication partner is switched off. CU230P-2 DP: - The PROFIBUS master is set to STOP. See also: p2040, p2047 Alarms, faults and system messages 11.12 List of fault codes and alarm codes SINAMICS G120XA PN converter 1274 Operating Instructions, 09/2025, FW V1.05, A5E51610273B-AC
Possible causes
Source: SINAMICS G120XA PN converter P1276
Series: G130-G150, S120-S150
"Fieldbus: Setpoint timeout"
converter
Meaning:
Possible causes
Source: SINAMICS G130_G150 P1175; SINAMICS S120_S150 P2071
Series: G200, G210X, S220
Fieldbus setpoint timeout
converter
Meaning: Reception of setpoints from the fieldbus interface (PROFINET) was interrupted. - The bus connection is open. - The controller is switched off. - The controller is set to STOP.
Possible causes
Source: SINAMICS G200 converter P683; SINAMICS G210X converter P937; SINAMICS S220 converter P2190
Series: S110
"PROFIBUS: Setpoint timeout"
servo drive
Meaning:
Possible causes
Source: SINAMICS S110 P722
Series: S200, S210
Fieldbus setpoint timeout
servo drive
Meaning: Reception of setpoints from the fieldbus interface (PROFINET) was interrupted. - The bus connection is open. - The controller is switched off. - The controller is set to STOP.
Possible causes
Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P499; SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1310